8
Sub menu 3 – Time
After entering this menu, the value of the hour will
start blinking. Using the
and
buttons, this
value can be changed. When this is set correctly, it
can be confirmed by pressing the
button.
Now the minutes value will start blinking, which
can be set in the same way as the hour value.
When this is set correctly, it is confirmed by
pressing
. Now it will return to the time sub
menu, and the specified time can be checked.
Sub menu 4 – Date
After selection of the sub menu with the
button, this sub menu can be changed by pressing
the
button. The day number will now start
blinking. Using the
and
buttons, the value
can be adjusted until the correct value is obtained.
The
button will confirm your setting. Now
the month number will start blinking. This can be
set in the same way as the day number. When the
month number is confirmed by pressing
, the
year number will start blinking. This can be set in
the same way as the day- and year number. When
this is confirmed by pressing
, it will return to
the date sub menu, and the specified date can be
checked.
Sub menu 5 – Pump test
In this sub menu, the pump can be tested. The
usefulness will be explained later in this section.
This menu can be selected by pressing the
button from the main menu. The display will show:
'Pump test?'. When
is pressed, the pump will
be activated for 30 seconds, independent of the
measured temperatures. After 30 seconds, the
display will show 'Pump test end', which can be
confirmed by pressing the
button again, and
it will return to the sub menu pump test.
Sub menu 6 – Code menu
This menu is to be used solely by the installer.
Entering the correct code will grant access to the
sensitive system settings. Read section 4.2.1 if you
are interested in what your installer can set for
you. Make sure your installer is aware of the
settings of the ventilation equipment. The
ventilation settings will influence the settings of
the Aquacom.
3.2 Tips for using the Aquacom
From the moment the Aquacom is attached to
your ventilation system, there are several
situations which should be taken into account
while using the unit.
-
The ventilation equipment will determine the
amount of air which will be drawn (through
the Aquacom unit). When this amount is
higher, more ground energy will be
transferred to the ventilation air. The achieved
temperature rise or drop however will be
lower.
-
When the Aquacom is turned off, the heat
exchanger can freeze during outside air winter
conditions and a high ventilation flow. Never
unplug the unit from the wall socket,
otherwise the frost protection will not work.
Also make sure enough anti-freeze is added to
the water.
-
For extreme winter temperatures (< -15°C)
and a high ventilation flow, the heat
exchanger can freeze. When extreme low
temperatures occur, never use the highest
ventilation mode.
-
When the heat recovery unit is engaged in the
'summer exitair only' mode, no air is drawn
and the Aquacom will not have any effect.
-
When the ground temperature will not have
any useful effect, the Aquacom will disable
itself. It will also enable itself by itself.
-
Do not adjust the (potential) bypass
temperature of the heat recovery unit. This
temperature ensures no condensation will
appear in the system.
-
The Aquacom unit will every two weeks at
least turn on for two minutes when the plug
in the wall socket. This will prevent the pump
from forming rust and getting stuck.
3.3 Maintenance by the user
Major maintenance of the Aquacom should
always be performed by a qualified installer.
Do not try to perform this as an end user.
When performing the requirements below, make
sure the plug is removed from the wall socket.
We recommend to commit every two years the
following the major maintenance on your
ventilation unit:
-
Check the fins of the heat exchanger for
damage
-
Clean the heat exchanger
-
Clean the drain
-
Check the pump operation
-
Check (and if necessary repair) the electrical
wiring.
-
Check the system pressure
-
Check the glycol content
In addition, we recommend cleaning the duct
system every six years.
Aquacom maintenance for the end user limits itself
to cleaning and replacing the filter. Also the