Technical Specification & Installation
Sentinel Kinetic MVHR Installation & Commissioning
4
Product Description
Sentinel Kinetic 200ZP, 200ZPH & 200ZPM
The Vent-Axia
Sentinel Kinetic Mechanical Ventilation / Heat Recovery (MVHR)
heat recovery unit is designed
for the energy efficient ventilation of houses and similar dwellings, conforming to the latest requirements of the
Building Regulations document F 2010.
The unit is designed for continuous 24 hour exhaust ventilation of stale moist air from bathrooms, toilets and
kitchens. As the stale air is extracted, a heat exchanger within the unit transfers the heat into the supply air entering
the bedrooms and lounge.
Sentinel Kinetic 200ZP, 200ZPH & 200ZPM Summer Bypass.
The Sentinel Kinetic
is fitted with a Summer Bypass (SBP) and will provide energy-free heating and energy-free
cooling when the house temperature and ambient temperature allows.
If the room is warmer than the set (shown as "indoor") temperature (i.e. you need the room to be cooler) and the
outdoor air is cooler than the actual room temperature (i.e. the outdoor air could cool your room) then the SBP will
open and the unit will supply cooler air to your room.
If the room is cooler than the set ("indoor") temperature (i.e. you need the room heating) and the outdoor air is
warmer than the actual room temperature (i.e. the outdoor air could heat your room) then the SBP will open and the
unit will supply warmer air to your room.
Note that the above only applies whilst the outdoor air temperature is above 14C (adjustable) in order to prevent cold
draughts.
The set ("indoor") temperature should be set 2 or 3 degrees higher than the central heating thermostat and 2 or 3
degrees below any air conditioning thermostat if fitted. This will prevent any clash between these separate systems.
Models
407161 - Sentinel Kinetic 200ZP
with Summer Bypass and Wired Remote Control.
407162 - Sentinel Kinetic 200ZPH
with Summer Bypass, Integral humidity sensor & Wired Remote
407476 - Sentinel Kinetic 200ZPM
with Summer Bypass and Vent-Wise PCB
Accessories
441838
- Sentinel Kinetic plug-in integral humidity sensor
441780
- Vent-Wise accessory pack (Requires sensors)
447340
- Opto Coupler
A range of sensors can be used to manage system demand and control the ventilation rate. These include an
internal humidity sensor, humidity sensors for independent mounting in rooms, CO
2
sensor, Vent-Wise sensors,
manual switches and pull cords. For these alternative control options, see www.vent-axia.com