Technical Specification & Installation
Sentinel Kinetic MVHR Installation & Commissioning
12
Connect Switches and Sensors
The unit can be switched to boost by a variety of methods:
Applying 240V to the LS input.
Switching across 1 of 5 pairs of switch terminals.
Applying between 0 and 10 V as a proportional input to two input terminals.
In addition, fitting a Vent-Wise Accessory to the unit means that switch terminals 1-3 can be connected to be
switched by a current detector (for example, detecting a hob being switched on) or a temperature sensor (for
example, detecting the flow of hot water). Terminal 4 can be used in conjunction with a momentary switch or
switches.
Connect any switches or sensors required to control the unit by connecting to the terminal connectors at the bottom
of the control board as shown below and in Table 1.
If necessary contact Vent-Axia regarding the wiring and fixing
of accessories and sensors.
Other means of connecting the
unit can be used if they meet the
local wiring regulations.