Commissioning
Sentinel Kinetic MVHR Installation & Commissioning
30
Table 3: Default Settings
Parameters
Settings
Start-up Screens
Software version
V--
Language
English.
Airflow Units
%.
Commissioning Screens
Security PIN
Not set
Boost Supply/Extract
50 %
Normal Supply/ Extract
30 %
Low Supply/Extract
20%
Cooker Hood
supply / extract
100%
Cooker Hood Antifrost
Priority
On but can be set Off
Boost Overrun
15
Boost Delay
00
Boost On/Off
All days set to 0:00 (on), 00:00 (off) – inactive
Normal On Off
All days set to 0:00 (on). 00:00 (off) – inactive
Set Service No
Not set
Humidity
70%
Proportional 1
Humidity – Boost, Normal (60 %)
CO2 – Boost (2000 ppm), Normal (1000 ppm)
Temperature – Boost (27 C, Normal (17 C)
Proportional 2
CO2 – Boost (2000 ppm), Normal (1000 ppm)
Temperature – Boost (27 C, Normal (17 C)
Humidity – Boost, Normal (60 %)
SW4
Off, or with Vent-Wise card fitted 25 minutes
Vent-Wise 1/2/3
Load Pot (60 %)
Time Pot (20 m)
Summer Bypass
Not Fitted
Antifrost
Airflow Mode
Dryout
Off
Running Time
-
Filter Life
Can be set to Urban Suburban and Rural
BMS
On
Restore Defaults
Off
User Screens
Set Clock
-
Summer Mode
Summer Mode On
Indoor Temp
25
C
Outdoor Temp
14
C