8.  REINSTALL BLOWER WHEEL AND BOTTOM PANEL

CAUTION

When reinstalling the blower wheel, make sure the small tab is aligned with the yellow label 
on the motor.

8.1

  Reinstall blower wheel: Using both hands, gently push on the blower wheel until secured.

8.2

  Insert bottom panel in the back of the hood.

8.3

  Secure bottom panel to the hood, using the 7 or 8 screws previously removed in step 

3.2

.

7. CONNECT 

WIRING

    WARNING

!

Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance 
with all applicable codes and standards. Before connecting wires, switch power off at 
service panel and lock service disconnecting means to prevent power to be switched on 
accidentally.

HE0059

G

ROUND

SCREW

Connect cable to range hood wiring 
using included wire connectors.

Connect BLACK to BLACK, WHITE to 
WHITE and GREEN or BARE WIRE 
to GREEN ground screw. 

DO NOT 

FORGET TO  CONNECT THE  GROUND.

HO0168

Содержание ISPIRA IU600ES SERIES

Страница 1: ...NER HOMEOWNER USE AND CARE INFORMATION ON PAGES 10 TO 12 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ONLINE AT www bnv ca For additional information visit www venmar ca 21224 rev 04 INSTALLATION INSTRUCTIONS ...

Страница 2: ...d ON when cooking at high heat or when flambeing food i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fan frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazar...

Страница 3: ... ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated airflow Refer to the table next page to help you plan the most efficient installation Install wall or roof cap once done ensure there is no leak in house insulation Connect metal ductwork to cap and work back towards the hood location If 6 round ducts are installed use a 3 x 10 to 6...

Страница 4: ...IU600ES30WG and IU600ES36WG models see service parts list on pages 14 and 15 NOTES 1 During installation protect countertop and or cooktop 2 If the bottom of the cabinet is recessed attach four 1 wide wood strips not included as shown at right in order to properly attach the hood to the cabinet The wood strips must be as thick as recess WARNING When performing installation servicing or cleaning th...

Страница 5: ... HOODS Remove the 7 screws A only retaining the bottom panel and set aside FOR 36 WIDE HOODS Remove the 8 screws A and B retaining the bottom panel and set aside Cut out the openings for duct A and power cable B in cabinet or wall according to the direction of discharge chosen See figures below C L HD0407A 3 5 5 3 B 1 DIA A 7 8 C L 7 8 3 5 5 2 HD0566A A CABINET BOTTOM 2 1 B 1 4 HORIZONTAL DISCHARG...

Страница 6: ...d nuts by hand Ensure glass panel is flush with top of hood and centered from side to side Then using a 3 8 socket tighten nuts completely 4 INSTALL GLASS PANEL WG MODELS ONLY The WG hood models decorative glass panel is sold separately and has to be installed before completing the hood installation 3 3 Using both hands gently pull on the blower wheel to remove Set blower wheel aside 3 PREPARE THE...

Страница 7: ...rming the installation make sure the adapter fits easily in the duct If this hood replaces an existing hood please note that location of the air exhaust can vary from one manufacturer to another FOR HORIZONTAL DISCHARGE ONLY Turn the hood over and remove the metal shutoff plate from the back of the hood by removing both retaining screws Set screws aside Fold down the foldable flange of the adapter...

Страница 8: ...er damper enters the duct opening Tighten the first 4 screws completely then add the last screws screws nos 5 6 7 8 and 9 in the center holes Make sure the damper flap opens freely Using two no 6 x 1 2 screws provided secure the adapter damper to the back of the hood Remove tape from damper flap Seal the adapter damper to the hood using metal foil duct tape FOR VERTICAL DISCHARGE ONLY Using two no...

Страница 9: ... screws previously removed in step 3 2 7 CONNECT WIRING WARNING Risk of electric shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally HE0059 GROUND SCREW Connect cable to range hood wiring using i...

Страница 10: ...pers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the hood During construction renovation cover the hood to make sure no dust sticks to stainless steel surfaces WARNING Before servicing or cleaning the unit switch power off at service panel and lock service panel to prevent power from being switched o...

Страница 11: ... 5 minutes and will stop automatically Selecting an other speed while the delay function is activated will not deactivate the function or reset the timer To cancel the delay function press the delay button once again or press the selected speed button which will also turn the blower off ii When blower is off it is possible to lock the control interface in order to clean the glass panel To lock the...

Страница 12: ... allows three different lighting levels according to your needs Press once for full intensity twice for intensity level 2 and once more for nightlight To turn off the lights press once more If desired when the lights are on press and maintain the light button for 1 second lights will be turned off NOTE When only the lights are ON to any intensity and no interaction with the hood is detected for a ...

Страница 13: ... GRN GREEN GRY GREY ORG ORANGE RED RED WHT WHITE YEL YELLOW COLOR CODE 16 Pins LED driver Input Output LED LED User interface 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 T1 FAN MOTOR User Interface J1 10VAC J8 Aux Input 3 2 1 RP1 J3 Programmer header Triac Ext J7 J11 12VDC J4 Motor Speed J2 120V Motor Lamp 1 J10 J9 Serial Com 5 4 3 2 1 J5 Output J6 Thermistor 2 3 4 5 1 2 3 4 1 2 1 2 1 2 3 4 1 2 1 2 3 PNK ...

Страница 14: ...14 14 SERVICE PARTS HL0224 1 2 3 4 5 6 7 8 9 10 11 ...

Страница 15: ...ature failing Venmar Ventilation ULC recommends to contact a certified service depot for all replacement parts and repairs KEY NO PART NO DESCRIPTION WIDTHS 30 36 1 SV09953XX GLASS PANEL 30 1 0 1 SV09954XX GLASS PANEL 36 0 1 2 22427 ELECTRONIC CONTROL 1 1 3 62612 LED MODULE 1 2 2 4 SV01766E WHEEL AND MOTOR 1 1 5 62053 HYBRID FILTER 15 875 X 14 x 0 5 1 2 2 6 21189 POWER UNIT 1 1 7 07325 TRANSFORMER...

Страница 16: ...tilation ULC Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation ULC s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation ULC ...