CONNECTION SCHEME
A) CONNECTION USING THREE WIRES.
Connect 13.8 Volt power supply coming from the control panel to the corresponding terminals:
-RIC negative; +RIC positive; +C positive-missing trigger.
NOTE: DIP-SWITCH no. 2 is set by the manufacturer in OFF position, POSITIVE-MISSING TRIGGER.
B) CONNECTION USING TWO WIRES
Connect 13.8 Volt power supply coming from the control panel to the corresponding terminals:
-RIC negative; +RIC positive. (make a jumper bC and +RIC).
NOTE: DIP-SWITCH no.2 is set by the manufacturer in OFF position, POSITIVE-MISSING TRIGGER
C) BLS TERMINAL, NEGATIVE INPUT FOR SOUND BLOCK
It activates the sound interruption trigger by taking a negative (0V) to terminal no. 4.
D) STI TERMINAL, SYSTEM STATUS NOTICE (PERMANENT/MOMENTARY ALARM SYSTEM ON/OFF)
DIP 3 in OFF position
Giving a positive to terminal no. 5, all LEDs of the flashing unit flash 3 times (ON). Anomalies are reset to zero.
Taking away the positive, all LEDs stay lighted up steady for 5 seconds (OFF) and the complete sounder test is launched. In
case of anomalies, they are duly notified.
PONT 1 (R74) – UNTOUCHED (STANDARD SETTING):
Momentary ON-OFF signaling and 1 LED keeps on flashing in intermittent mode
until there is positive signal to terminal no. 5
.
PONT 1 (R74) – CUT:
Momentary ON-OFF signaling
GND 0V
+13.8Vdc and SOUNDER TRIGGER
TAMPER LINE
CONTROL PANEL
GND 0V
+13.8V
OUTDOOR SOUNDER TRIGGER
TAMPER LINE
CONTROL PANEL