Voltage  

Nominal power supply voltage 

13.8 Vdc        

Minimum – maximum command limits 

4 Vdc – 5.4 Vdc; 10.8Vdc – 11.9Vdc; 
0.51Vdc – 1.55Vdc 

Minimum power supply 

10.5 Vdc       

Maximum power supply 

15.5 Vdc      

 
Current 

Sound consumption from battery 

1.3 A +100/-300 mA 

Maximum continuous recharge 

700 mA  

 100 mA 

Flashing unit consumption 

80 mA  

 10 mA 

Consumption in stand-by 

15mA 

Consumption from control inputs 

+0.5 mA @Vc=12V; -0,3 mA @Vc=0V 

Open collector 

-10mA max 

LED flashing unit life 

 

1,000,000 flashes 

Timing 

 

3 minutes, settable at 8 minutes 

Battery capacity 

 

12V 2.0 Ah 

Switch tamper range  

N.C. 

0.2 A max. 

Fundamental frequency 

All models (DIP 4 in OFF position, CERTIFIED TONE

1435 Hz

 

Sound pressure dB (@) at 1 m 

All models 

SEE DIAGRAM 

Mechanics 

 

 

External cover 

TRIADE L – TRIADE LS – TRIADE QL – TRIADE QLS 

Painted ABS 

RIALTO L – RIALTO LS  
LIDO L – LIDO LS  

Painted steel  

 

RIALTO X – RIALTO LSX  
LIDO X - LIDO LSX 

Stainless steel 

Internal cover 

 

Zinc-plated steel 

Flashing unit lens 

 

Polycarbonate 

Protection degree 

 

IP 44 

Environmental class 

 

IV (outdoor) 

Operating Temperature 

 

From -25°C to +55°C 

Size 

RIALTO 

206 x 206 x 97 mm (H x L x P)  

TRIADE 

245 x 250 x 97 mm (H x L x P) 

LIDO 

252 X 206 X 110 mm (H x L x P) 

Weight 

RIALTO 

2,564 g 

TRIADE 

2,082 g 

LIDO 

2,951 g 

Standards compliance 

Certifying body 
(IMQ-SISTEMI DI SICUREZZA) 

EN50131-4:2019 

Security degree 

L, LS and LSX models 

Degree 3 

Содержание RIALTO L

Страница 1: ...timings alarm counting optical and acoustic signaling of System ON OFF arming disarming electronic circuit protected against polarity inversion and tropicalized by resin immersion microprocessor self...

Страница 2: ...TERMINAL NEGATIVE INPUT FOR SOUND BLOCK It activates the sound interruption trigger by taking a negative 0V to terminal no 4 D STI TERMINAL SYSTEM STATUS NOTICE PERMANENT MOMENTARY ALARM SYSTEM ON OFF...

Страница 3: ...5 STI to 12V for 10 seconds then take away the voltage from the terminal These steps launch the test which will last 60 seconds During the test the sounder verifies its own functioning and notifies an...

Страница 4: ...ive missing alarm if disconnected or 0V ON Negative missing alarm if disconnected or 12V Chart 6 TONE SELECTION DIP 4 TONE FREQUENCY LIMITS Hz OFF default setting CERTIFIED Increasing Continuous Decre...

Страница 5: ...nd the power supply to the control panel 5 Close both internal and external covers using the screws provided 6 Battery must have UL94 HB flammability rate 7 Power supply must be of SELV type Attention...

Страница 6: ...5 mA Vc 12V 0 3 mA Vc 0V Open collector 10mA max LED flashing unit life 1 000 000 flashes Timing 3 minutes settable at 8 minutes Battery capacity 12V 2 0 Ah Switch tamper range N C 0 2 A max Fundament...

Страница 7: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 7 of 8 NOTE...

Страница 8: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 8 of 8 Via del Lavoro 10 30030 Salzano VE Tel 39 041 5740374 Fax 39 041 5740388 Web site www venitem com E mail info venitem com...

Отзывы: