35
For example: “PT?aktmr.atmrc…atpsmrbveinc?”. In this case the telephone number in position 1
receives the communications for zone alarm, zone alarm call, zone tamper, mains failure and mains
restore; the telephone number in position 2 receives the same communications as the telephone in
position 1, with the added possibility to control CTH-18 via SMS and App; the telephone numbers
in position 3,4,5 are not programmed; the telephone number in position 6 is set to receive every
communication and to control CTH-18 via SMS and App.
DISPLAY OF TELEPHONE NUMBERS CONFIGURATION: To receive the telephone numbers configuration,
you just need to send the SMS “VP”.
SOUNDER OPTIONS
You can configure CTH-18 options by sending an SMS of configuration: SMS “PA?
A.B.C.D.E.F.G.H.I.J
?”.
Fields marked in red must be filled out according to the chart below. It is mandatory to enter each field:
OPTION DESCRIPTION
TEXT MESSAGE
A
Setting of the alarm duration for CTH-18 in the event of
zone, tamper or panic alarm
“1” for 30 seconds
“2” for 60 seconds
“3” for 120 seconds
“4” for 180 seconds
B
Setting of entrance timing
“1” entrance timing 15 seconds
“2” entrance timing 30 seconds
C
Activation/deactivation of the control for the supervision
signal sent from the devices
“0” control disabled
“1” control enabled
D
Setting of the number of alarms to be sent from one
zone to be automatically bypassed from the system
“0” no alarms limit
“1” 2 alarms
“2” 4 alarms
E
Setting of the time after which SMS for mains
failure are sent
“1” 30 minutes
“2” 60 minutes
“3” 120 minutes
“4” 240 minutes
F
Setting of the flashing unit for the permanent
notification of system status
“0” LED for system status
deactivated
“1” LED for system status active
G
Setting of the operation of OUT1 output
“0” bistable output
“1” time-controlled exit 2 seconds
“2” time-controlled exit 30 seconds
“3” time-controlled exit 60 seconds
Содержание CTH-18
Страница 1: ...CTH 18 EN MANUALE TECNICO TECHNICAL MANUAL IT...
Страница 2: ......
Страница 4: ......