background image

S T   /   V T   V E N D O R  

  3 5 6 8   3 5 6 7   3 5 6 6   3 5 6 5  

   

12

 

4 2 2 0 5 5 7   R E V   A

 

PRESS SERVICE 

MODE BUTTON 

AND PRESS 1 TO 

ENTER TUBE FILL 

MODE  

 

INSERT COINS THROUGH 

FRONT DOOR COIN 

INSERT TO FILL COIN 

TUBES 

Loading Coin Mechanism

 

The Coin Mechanism must be loaded with some level of each coin in 
order  for  the  vendor  to  operate  properly.  The  coins  need  to  be 
loaded  into  the  coin  mechanism  by  insertion  into  the  front  coin 
insert.  First enter the SERVICE MODE then TUBE FILL MODE 
(See SERVICE MODE instructions 

 COIN/TUBE FILL MODE  

Each tube should be kept loaded with at  least one roll of each coin 
to keep above the tube low level sensors. Once the tubes are loaded 
to  these  levels  the  Dollar  Bill  Validator  will  accept  bills.  If  the  coin 
tubes  fall  below  this  level  the  Dollar  Bill  Validator  may  stop 
accepting  bills  and  the  front  display  will  indicate  "EXACT  CHANGE 
ONLY". 
Alternatively, you can load the coins into the slots above the respective coin tubes, making sure  to load the 
correct coins  into  their correct tubes.  This  is  not the  preferred  method.  By  using  TUBE  FILL  mode  the  control  board  can  then  accurately 
determine coin levels. 
On some Coin Mechanisms there are buttons above each tube to dispense the coins (may vary depending on which coin mechanism that is 
used).  The coins can also be dispensed within the Service Mode described later. 

 

Bill Validator Operation 
(OPTIONAL) 

To  remove  the  bills  from  the  Dollar  Bill 
Validator  push  the  tab  on  the  top  of  the 
bill  box  and  lift  up.  To  clear  jams  or 
cleaning  unlatch  lower  unit  as  shown.  
Dollar  Bill  Validator  cleaning  instructions 
as  well  as  more  advanced  service 
information  can  be  obtained  on  the 
Service  portion  of  the  website  listed  at 
the beginning and end of this manual.

 

 
 

AUTOMATIC DELIVERY LIFT (OPTIONAL) 

This information is for machines with the GVC2 Control Board (part number 4214682.004) and software version V3.3.10177 and higher. 

 

INTRODUCTION 

The Automatic Delivery Lift system is designed to lift vended products to the 2012 American Disabilities Act (ADA) height requirement level 
from the locations floor.  This same system can also provide an enhanced customer experience for those locations where an almost hands 
free vended product presentation is desirable. 

The  Delivery Lift  system  is  an  option  that can  be  used  on  the  line  of  Delivery Lift  Ready  Machines  (also  called  ADA  ready  machines)  and 
consists of an LED illuminated product delivery box with a motorized product lift plate, a set of product height sensors, a motorized delivery 
box door (Auto  Door) and a Blue LED illuminated activation button.   

The delivery lift system can be factory installed or provided as a retrofit kit for field ADA ready machines. See the list of ADA ready model 
numbers or contact a sales or service representative for more information.     

 

INITIAL SETUP 

 SERVICE MODE 

When an Automatic Delivery Lift system is installed in an ADA ready machine, it is automatically detected when a controller Service Mode 
Motor Count is done. The Motor Count will show the tray motor count briefly with the 3 additional delivery lift motors before returning to 
a  tray  motor  count  only.  Once  a  Delivery  Lift  system  is  detected,  it  will  complete  a  functional  test  at  every  Motor  Count  or  at  machine 
power on. When the Delivery Lift is moving, the Blue Delivery Lift Button on the front of the machine will flash and can be pressed to stop 
the Delivery Lift operation if necessary. Information on Service Mode Configuration menu and Diagnostic Mode menu options are listed on 
the following pages.   

 

SALES MODE 

When a product is selected and vended, the product drops into the Delivery Lift Box after it first passes by the iVend sensor to confirm that 
a product has been vended. Next, when the machine is using the default BUTTON configuration mode, the Blue Delivery Lift Button will be 
constantly  illuminated  for 10 seconds,  during  this  period  the  Delivery Lift  can  be  activated.  When  the  illuminated  button  is  pressed,  the 
Delivery Door will open, the Delivery Lift will begin raising the vended product and the button will flash. The product will be raised until a 

Содержание ST 3000

Страница 1: ...3 5 6 5 3 5 6 6 3 5 6 7 3 5 6 8 4 2 2 0 5 5 7 R e v A ST VT SINGLE TEMP VARIABLE TEMP GLASS FRONT VENDOR MODELS 3567 3567A ST 3000 3 WIDE 3565 3565A ST 5000 5 WIDE 3568 3568A VT 3000 3 WIDE 3566 3566...

Страница 2: ...S T V T V E N D O R 3 5 6 8 3 5 6 7 3 5 6 6 3 5 6 5 2 4 2 2 0 5 5 7 R E V A...

Страница 3: ...FT 12 VEND CYCLE IVEND EQUIPPED 13 SALES MODE 14 BASIC PROGRAMMING SETUP 14 SERVICE MODE 14 SERVICE MODE FUNCTIONS 15 1 TUBE FILL DISPENSE COINS 15 2 MOTOR COUNT 15 3 OPTIONS 15 4 CONFIGURATION 15 5 P...

Страница 4: ...aporator coils up the back air duct and circulates down through the trays There are openings in the bottom trays to allow air to circulate around the products All programming pricing vend functions an...

Страница 5: ...carrier not the manufacturer within 15 days after receipt of the vendor Carefully remove the outside packing material so as not to damage the finish or exterior of the vendor Inspect the vendor for c...

Страница 6: ...32 hex socket Allen screws fastening the top hinge assembly to the top of the door see Figure 4 Once these screws are removed the door needs to be lifted vertically off the bottom hinge The bottom hi...

Страница 7: ...and regulations before installing the vendor Refer to the Safety Installation Guidelines document found in the service package shipped with your vendor Before connecting the vendor the integrity of t...

Страница 8: ...PTION To unlatch the Can Bottle Trays place both hands with your palms up then push out simultaneously with your thumbs depressing the slide left and right side latches and pullout as shown See Fig 10...

Страница 9: ...evers all the way down this guides the tray for tilting when loading 11 Re install the tray plug into its receptacle on the right side wall 12 Re engage the tray harness into its harness retainer See...

Страница 10: ...ions a wide variety of selection compartment widths can be obtained as required See Figure 16 The dividers can be located in every Candy position This adjustment provides for CANDY candy bars crackers...

Страница 11: ...le is The narrower the product the higher the timing Thick Products 4 6 o clock Most products 6 o clock Thin Products 6 8 o clock TO CHANGE SNACK CANDY FOOD SPIRAL TIMING 1 Remove the motor cover 2 Ra...

Страница 12: ...is designed to lift vended products to the 2012 American Disabilities Act ADA height requirement level from the locations floor This same system can also provide an enhanced customer experience for th...

Страница 13: ...ed damaged or disconnected the normal home switch vend cycle will be used and the optical sensors will be ignored Both the vend motor and a vend timeout timer are started The selection motor rotates t...

Страница 14: ...of the manual includes only basic Service Mode Programming functions Refer to the CONTROL SYSTEM Programming Manual included with the vendor for more advanced description of all functions within the S...

Страница 15: ...to dispense quarters 0 25 coins 3 Press to dispense dimes 0 10 coins 4 Press to dispense nickels 0 05 coins 5 Press 2 times to exit Sales Mode Note For dispensing more than a 4 denomination coin mech...

Страница 16: ...every item all at once Time Saving Suggestion Instead of setting the price of each item one at a time it is much faster to set the common price of the entire vendor then go back and set the price of...

Страница 17: ...OL SYSTEM Programming Manual for more information 8 TEST VEND SINGLE MOTOR Use this menu to test vend individual motors The selection will display with the test vend If a test vend attempt on a partic...

Страница 18: ...determine the Auto Door position when the sales mode is entered or while in the sales mode the machine will be placed Out of Service 0 0 3 DELIVERY LIFT TEST Raises and lowers the Delivery Lift plate...

Страница 19: ...ontrol system The refrigeration and optional heater systems are activated depending on the target temperature setting or SET POINT The total allowable temperature variation from the SET POINT is DELTA...

Страница 20: ...off A 30 minute door timer starts and a compressor delay timer starts If the door is open for more than 30 minutes the controller will resume closed door operation the message DOOR ALERT is displayed...

Страница 21: ...y every 10 seconds 3 During the 1 to 3 minute period enter service mode and activate the Health Test Mode see steps below this will override the 15 minute delay that is normally imposed before activat...

Страница 22: ...minus half of DELTA CUT OUT The heater turns off if SENSOR2 reading equals the SET POINT or if the compressor is on REFRIGERATION To prevent damage to the refrigeration unit when it is turned off or...

Страница 23: ...ol circuit Unplug power to the vendor Open the power panel Use insulated jumper wires to short the wire terminals on Relay 1 between 2 and 4 and between 6 and 8 Restore power to the vendor The compres...

Страница 24: ...r has been moved or remounted to wrong position REFREGERATED SPACE TO COLD 1 Refrigeration setting to cold See Refrigeration Setting instructions in machines programming manual 2 Faulty refrigeration...

Страница 25: ...including baking soda or ammonia in the cleaning solution Plastic parts may be cleaned with a quality plastic cleaner The vend mechanisms must be kept clean Any build up can cause the mechanisms to m...

Страница 26: ...the invoice should be sent 4 The number of parts required 5 Always refer to the pertinent parts and or part manual for the correct part number and description of a specific part NOTE When RIGHT or LE...

Страница 27: ...r from cooling in between workout cycles Is the circuit breaker at the fuse box reset Is the evaporator fan working To check if the fan is running take a small piece of paper in front of the evaporato...

Страница 28: ...s warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications...

Отзывы: