S T / V T V E N D O R
•
3 5 6 8 3 5 6 7 3 5 6 6 3 5 6 5
•
11
4 2 2 0 5 5 7 R e v A
IF AFTER ADJUSTING THE SPIRAL END THE
PRODUCT STILL DOESN'T FALL OFF TRAY …
SNAP
PROVIDED PRODUCT PUSHERS ONTO END OF
SPIRALS TO ENSURE PRODUCT WILL FALL
ADJUST SPIRAL END POSITION FOR SUCCESFUL VEND.
MOST PRODUCTS VEND PROPERLY AT THE
6:00 (0'CLOCK) SETTING
SHOWN ABOVE
ADJUST SPIRAL
COUNTER CLOCKWISE
FOR THICKER
PRODUCTS
(i.e. 3:00 (0'CLOCK))
ADJUST SPIRAL
CLOCKWISE FOR
THINNER PRODUCTS
(i.e. 7:00 (0'CLOCK))
ADJUST SPIRAL END POSITION BY PINCHING
SNAP TABS OF SPIRAL COUPLING ON BACK
OF MOTOR - PULL OUT OF MOTOR THEN
SNAP BACK INTO DESIRED POSITION
SPIRAL ADJUSTEMENT
The shape, size and thickness of a product affect how well it falls off the tray. Most products can be vended successfully when the spiral
end is positioned at 6 o’clock. If vending problems occur with spiral ends at the standard 6 o’clock position,
adjust the drop-off either by
retiming the spiral or installing a Product Pusher
.
SPIRAL TIMING
SNACK/CANDY/FOOD TRAY
Each spiral can be rotated in 20º (degree) increments
for a different drop-off point. Most products can be
vended successfully when the spiral end is positioned
at
the 6 o’clock position.
The general rule is:
The narrower the product, the higher the timing.
Thick Products - 4-
6 o’clock
Most products
–
6 o’clock
Thin Products - 6-
8 o’clock
TO CHANGE SNACK/CANDY/FOOD SPIRAL TIMING:
1.
Remove the motor cover.
2.
Raise the motor slightly and pull forward on the spiral until it separates from the motor.
3.
Rotate the spiral to the desired position and re-insert the hub (spiral coupling) into the motor.
The hub must be seated over the vertical rail or retaining rib on the tray as shown (See Figure
17).
4.
Replace the motor cover, making sure it is securely tightened.
5.
Test-vend to make sure
product vends properly.
FIG 17.: Spiral and Motor Connection
TO CHANGE CAN/BOTTLE/HCCT SPIRAL TIMING:
Each spiral can be rotated in 45º (degree) increments for a different drop-off point. Most products can be
vended successfully when the spiral end is positioned at 6 o’clock.
1.
Reach behind motor to release spiral coupling from motor. Pinch spiral coupling ends and pull forward on
spiral to remove.
2.
Rotate the spiral to the desired position and re-insert
the spiral coupling into the motor. The spiral coupling
must be fully seated into the motor.
3.
Test-vend to make sure
product vends properly.
Product Pushers
If the product still will not vend properly after re-timing of the spiral then install a Product Pusher. The Product Pushers are provided in the
service package of the vendor. Snap onto spirals only as necessary as shown.