background image

10.  Installing top canopy: 

a. 

Softly coil all cables and gently tuck them around mounting bracket. 

b. 

Raise top canopy, safely covering all cables, aligning canopy with the screw on hanger,  

 

fasten it to the hanger and turn it counter clockwise to lock the screw. 

Remote Control Operation Guide

1.  Remote Pairing:

2.  Buttons:

Screws

Screws

Mounting
Bracket

Canopy

a. 

Power on the fan and press and hold “OFF” button within 10 seconds.

b. 

Hold “OFF” button for 2-5 seconds until you hear a “beep” sound 

 

confirming pairing.

c. 

Operate and test. Blades must be attached or fan will not continue.

*If pairing fails, please repeat steps. Hold remote close to receiver. 

“OFF” Button

Switches ceiling fan off

“S/W” Button

Summer/Winter button to change fans spin direction, 
forward and reverse

1-5 Speed Buttons

Fan Speed Options: Fan Speed Options:  
#1 – Lowest Speed (Night Mode)
#5 – Highest Speed

2H / 8H Timer Functions

Preset timer for automatic fan and light stop. 
2H – Fan turns off after 2 Hours
8H – Fan turns off after 8 Hours

 Light Button 

(If Light Kit Attached)

Button to control Light kit 
On / Off – Turn Light on or off
On / Off / On (Within 3 sec) - for Light colour change 
(3000K/4000K/5700K)
*Light will remember last light colour selected. 

“+” “-“  Dimming Buttons

Adjust the brightness of LED Lights
“+” – Increase the brightness of Light
“-“ – decrease the brightness of Light

11

Содержание Raven

Страница 1: ...ATTENTION TO INSTALLERS This DC ceiling fan requires complete assembly and installation BEFORE testing for correct operation RAVEN Instruction Manual and Warranty Form...

Страница 2: ......

Страница 3: ...7 Installing Mounting Bracket 7 Assembling Installing Ceiling Fan 8 Wiring Connections 10 Remote Control Operation Guide 11 Trouble Shooting 12 Ripple Control 13 Warranty claim on installed products...

Страница 4: ...nd Battery or other alternative power methods will not be covered under the terms of this warranty 12 Use ONLY the Vencha controller supplied with your fan Use of non standard or solid state dimmer ty...

Страница 5: ...d contact Vencha for assistance before commencing assembly or installation Warning Do Not use a dimmer or power regulator to control this fan Before Installation Parts Identification Tools Required Ph...

Страница 6: ...or Cover Lamp connector plate Without light cover Light Kit Fan blade 3 Fan Blades x3 Light Kit Canopy 5 Inch Downrod Motor Cover DC Inverter Motor Lamp Connector Plate Without Light Cover Receiver an...

Страница 7: ...e fan is fully undercover with a minimum of two walls This fan is not waterproof and must be installed in a location protected from water wind dust and salt Exposure to these elements will void the wa...

Страница 8: ...w holes and lock it with the screws c Align LED lamp panel and lock in with screws d Connect LED lamp through quick connecters once connected tighten all screws e Place lamp cover in plate and screw t...

Страница 9: ...he hanging bracket Pin Hanging Ball R Pin Bolt Warning Electric Drills can over tighten screws and damage thread causing inconsistent balance and rattling during operation Blades damaged from the use...

Страница 10: ...of this standard A single pole switch also must be placed in the same room as ceiling fan as per local wiring regulations AS3000 Multiple Fans If there are two or more DC ceiling fans installed in th...

Страница 11: ...ll not continue If pairing fails please repeat steps Hold remote close to receiver OFF Button Switches ceiling fan off S W Button Summer Winter button to change fans spin direction forward and reverse...

Страница 12: ...rect position in bracket Noisy Blade Screws are loose Check that all screws are securely tightened Do NOT overtighten Canopy touching ceiling Lower the top ceiling canopy so it doesn t make contact wi...

Страница 13: ...ugh Australia particularly areas of NSW and QLD use a ripple control signal on their distribution networks to remotely control demand devices like off peak hot water heaters and to implement different...

Страница 14: ...vered by warranty and service fees will apply If goods fittings are found to have been damaged or made faulty through no fault of Vencha then all costs incurred by Vencha as a result of your warranty...

Страница 15: ...products not operated in accordance with the instructions for use or specifications 5 Vencha products that have been modified in any manner painted or used with non standard blades controllers Includ...

Страница 16: ...fts etc for accessing products installed at a height of greater than 3 0 meters 16 Transportation and in transit insurance costs if the product or parts thereof have to be returned for repair or repla...

Страница 17: ...work commencing and an VRN number allocated by Vencha office Where a service call is undertaken and no fault is found with the ceiling fan or where the fault is not covered under the terms of this war...

Страница 18: ...f of Installation Certificate of Compliance First Name Last Name Address of Installation Address Line 2 City State Post Code Contact Number Mobile Number Email Signature First Name Last Name Installer...

Страница 19: ...1 6 Boden Rd Seven Hills NSW 2147 P 02 8811 1622 E sales vencha net au W www vencha net au...