Fixed washing plant
MODULA PLUS 2
Draft Vema Srl
45
6
MA
IN
TE
NA
NCE
PROBLEMS
CAUSES
REMEDIES
The system does not
reach the maximum
pressure.
The regulating valve is set for a
value lower than the operating
value
Adjust the valve "see relative
paragraph"
Lack of range in power supply
Check that the tap is completely open
and that the water flow is sufficient.
The nozzle is worn.
Replace the nozzle.
Poor detergent suction or
not very consistent foam.
The foam injector is clogged.
Remove and clean
Detergent suction filter clogged.
Clean the detergent filter
The cleaning agent used is too
viscous.
Use only detergent recommended by
the manufacturer, following the
dilutions indicated on the package.
There is no detergent
Check
No compressed air (only on air
models)
Check
Noise
The pump does not rotate freely
(friction resistance)
Contact the service center