Velocity VDOT-H2 Скачать руководство пользователя страница 19

 

GLT-299-7-2(3) Rev.0 

Mar 23, 2018 

 

 

19 

 

FOR WARRANTY SERVICE, RETURN TO: 

ZETA ALARMS LIMITED 

72-78 MORFA ROAD, SWANSEA, SA1 2EN 

http://www.zetaalarmsystems.com 

 

Section 12 

– WARRANTIES 

12.1.   

Zeta warrants to the customers that: 

(a) 

all  products  supplied  hereunder  will  be  of  merchantable  quality  and  will  comply  with  any  specification 

agreed between Zeta and customer. 

(b) 

it  is  not  aware  of any  rights  of any  third  party  in  the  market which  would  or  might render  the  sale  of the 

products, or the use of any of the trade marks on or in products, or the use of any of the trade marks on or 

in relation to the products, unlawful. 

12.2.  In the event of any breach of the Zeta's warranty in Clause 12.1(a) whether by reason of defective materials, 

production faults or otherwise, Zeta's liability shall be limited to: 

(a) 

replacement of the products in question; or 

(b) 

at the Zeta

’s option, repayment of the price where this had been paid. 

And the warranty period is three (3) years from the shipment from Zeta

’s factory. 

12.3.  Notwithstanding anything to the contrary in this warranty terms,  Zeta shall not be liable to the customer by 

reason  of  any  representation  or  implied  warranty,  condition  or  other  term  or  any  duty  at  common  law,  or 

under  the  express  terms  of this  warranty  terms,  for  any  consequential  loss  or  damage  whether  for  loss  of 

profit  or  otherwise  and  whether  occasioned  by  the  negligence  of  Zeta  or  its  employees  or  agents  or 

otherwise, arising out of or in connection with any act or omission of Zeta relating to Velocity or supply of the 

products, their use by any customer. 

12.4.  Customer  shall  indemnify  Zeta  against  all  loss,  damages,  liabilities,  costs  and  expenses  which  Zeta  may 

suffer or incur as a result  of or in connection with any breach by customer of this warranties terms or  any 

laws or regulations of any jurisdiction or any rules of any governing authorities. 

 

Содержание VDOT-H2

Страница 1: ...der chemicals or hydrogen sulphide may occur or affect the product It may cause damage to equipment Section 1 INTRODUCTION 1 1 General description The VDOT H2 and VDOT H2 H is an attractively styled l...

Страница 2: ...es an alarm in response to both 8 3 C 15 F rate of rise temperature or a 57 C 135 F fixed temperature alarm point The VDOT H2 H initiates an alarm in response to 83 C 181 F Heat detector incorporates...

Страница 3: ...RMINALS The VDOT H2 and VDOT H2 H heat detectors all have three terminal connections and the terminals are configured as follows Terminal Description 1 SLC Positive 6 SLC Negative 3 To activate VDOT S...

Страница 4: ...VDOT UB4 Standard mounting base GLT 299 7 6 4 inch 4 X X VDOT UB4 6 Larger mounting base GLT 299 7 7 6 inch 4 X X VDOT S6 Base Sounder mounting base GLT 299 7 10 6 inch 5 X VDOT STB RL Relay mounting...

Страница 5: ...the detector at least 10 cm 4 in from the wall The detector should not be installed in places such as Place with plenty of air flow close to a ventilation fan air conditioner or place with drafts Pla...

Страница 6: ...nted as a square Actual detector coverage covers a circle whose radius is 0 7 times the listed spacing Since all of the area within the detector s circle of coverage is suitable for detecting a fire t...

Страница 7: ...A A A B B B B C C C C D D D D Listed Spacing 9 1m x 9 1m 84m2 30ft x 30ft 900ft2 A 7 6m x 10 4m 79m2 25ft x 34ft 850ft2 B 6 1m x 11 3m 69m2 20ft x 37ft 740ft2 C 4 6m x 11 9m 54m2 15ft x 39ft 585ft2 D...

Страница 8: ...table here Ceiling Sidewall Note Measurements shown are to the closest edge of the detector Figure 5 Detector placement near ceiling or wall joints The following figure shows the required heat detecto...

Страница 9: ...84 4 3 to 4 9 m 14 to 16 ft 77 4 9 to 5 5 m 16 to 18 ft 71 5 5 to 6 0 m 18 to 20 ft 64 6 0 to 6 7 m 20 to 22 ft 58 6 7 to 7 3 m 22 to 24 ft 52 7 3 to 7 9 m 24 to 26 ft 46 7 9 to 8 5 m 26 to 28 ft 40 8...

Страница 10: ...4 m 8 ft on center If beams are greater than 46 cm 18 in in depth and are spaced more than 2 4m 8 ft on center then each bay formed by the beams must have at least one detector mounted on the ceiling...

Страница 11: ...iew Notes Detectors can be installed on the bottom of beams when the beams are less than 30 cm 12 in deep and beam spacing is less than 2 4 m 8 ft Beams less than 20 cm 8 in deep are considered flat c...

Страница 12: ...end of the ceiling Additional detectors if required must be located based on the horizontal projection of the ceiling and the type of ceiling construction For a ceiling slope of less than 30 degrees...

Страница 13: ...re 14 2 Using the VDOT AD2 Address Programmer set the desired address for each heat detector See Annex A for the handling 3 Install the heat detector into the mounting base making sure the wiring does...

Страница 14: ...o each loop Use cable AWG12 20 for wiring Do not connect different gauge cables at one terminal in order to prevent loosening CAUTION Do not connect cables in reverse polarity Failure to connect the p...

Страница 15: ...nsors must be tested after installation and periodically thereafter Testing methods must satisfy the Authority Having Jurisdiction AHJ When carrying out site testing of the detector the control panel...

Страница 16: ...nue as long as the outer ring makes contact with the ceiling b Hold the Heat Detector Tester over the detector until the detector alarms 7 Remove the Heat Detector Tester from the detector to stop tes...

Страница 17: ...tric shock CAUTION 1 Carefully remove the detector head from its base 2 Use a soft lint free cloth moistened with alcohol for sticky deposits to clean the plastic enclosure 3 Using a soft bristle brus...

Страница 18: ...del VDOT H2 0 C to 65 6 C 32 F to 150 F Model VDOT H2 H Operating Temperature 10 C to 55 C 14 F to 131 F Model VDOT H2 10 C to 65 6 C 14 F to 150 F Model VDOT H2 H Storage Temperature 20 C to 60 C 4 F...

Страница 19: ...stion or b at the Zeta s option repayment of the price where this had been paid And the warranty period is three 3 years from the shipment from Zeta s factory 12 3 Notwithstanding anything to the cont...

Страница 20: ...place Figure A 1 Mounting a detector on VDOT AD2 3 Press the Search Key a Buzzer sounds then the VDOT AD2 starts transmitting to the detector b Do not remove the detector when transmitting or damage c...

Страница 21: ...new address 2 Press the Set key a The buzzer sounds and all LED s are turned off The VDOT AD2 then starts transmitting to the detector b Do not remove the detector 3 The 7 segment LED shows the new ad...