1.  Introduction 

 

To all residents of the European Union 
Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. 
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling. 
This device should be returned to your distributor or to a local recycling service. 
Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 
Thank you for buying the 

PMR3

. This device comes with an earphone with microphone, which is also available separately (order code 

PMR3MIC). Read this manual carefully before bringing the device into service. 
 
Only for use in following countries: Austria, Belgium, Bulgaria, Cyprus, Denmark, Estonia, Finland, France 

(*)

, Germany, Greece, Hungary, 

Iceland, Ireland, Italy, Latvia, Czech Republic, Liechtenstein, Lithuania, Luxemburg, the Netherlands, Norway, Portugal, Slovenia, Spain, 
Sweden, Switzerland, Turkey, United Kingdom. 
 

(*)

 The use of channel 1 and 2 is not allowed in France. Consult the local authorities for proper usage of this device in your country. 

 

2.  Features 

 

a. Buttons and Controls 

 

1.  On/off  volume control 

7.  Jack for charger 

2.  PTT key 

8.  Earphone/mic jack 

3.  MON key 

9.  Soft antenna 

4.  Channel down key (

10. LCD display 

5.  Call key 

11. Channel up key (

6.  Microphone 

12. Speaker 

 
 

b. Display

 

 
1.  Key lock icon 
2.  Call: shown when calling another unit 
3.  TX: transmit indicator: indicates the unit is transmitting 
4.  RX: receive indicator: indicates the unit is receiving 
5.  Battery level indicator:  

 Batteries OK 
 Batteries low: when this icon is blinking and the device emits a low battery sound alert  

(sounds every 3 minutes), it is recommended to install new batteries or recharge them. 

6.  Channel number display 
 

3.  Installing / Recharging Batteries 

 
1. Make sure the unit is switched off. Press the button on the belt clip and turn it 90° clockwise or counterclockwise. 
2. Open the battery compartment and take the battery compartment cover off. 
3. Insert 3 AAA-batteries, respecting the polarity. 
4. Put the battery compartment cover back on & lock it. Rotate the belt clip back into its normal position. 
Always replace all batteries at once. Do not mix old with new ones. Do not mix different battery types or batteries of different capacity. Do not 
mix rechargeable and non-rechargeable batteries. 
 
Rechargeable batteries and an adapter are available as an optional accessory pack (order code 

PMR3AP

). 

If you've installed rechargeable batteries: 
-  The charging time is approximately 5 hours (which gives you a standby time of 10 to 15 hours, or 2 to 3 hours of continuous use) 
-  Plug the charging adapter into the jack (fig.1 #7) and switch on the 

PMR3

. The battery level indicator (fig.2 #5) flashes while the batteries are 

charging and stops flashing when the batteries are fully charged. 

-  The unit can still receive signals while it is being charged, but the CALL and PTT functions are unavailable. 
 

 

 

Fig.1 

Fig.2 

Содержание PMR3

Страница 1: ...key 6 Microphone 12 Speaker b Display 1 Key lock icon 2 Call shown when calling another unit 3 TX transmit indicator indicates the unit is transmitting 4 RX receive indicator indicates the unit is re...

Страница 2: ...normal status Do not use the MON function when the transmission is OK it will only result in more background noise f Key Lock Press the Call key fig 1 5 and the up fig 1 4 or down fig 1 11 key simult...

Страница 3: ...n in this manual is subject to change without prior notice PMR3 PMR ZENDER ONTVANGER 1 Inleiding Aan alle ingezetenen van de Europese Unie Belangrijke milieu informatie betreffende dit product Dit sym...

Страница 4: ...er 5 uur goed voor een waaktijd van 10 tot 15 uur of 2 tot 3 uur continu gebruik Sluit de adapter aan op zijn aansluiting fig 1 7 op de PMR3 en zet deze aan De indicator van het batterijniveau fig 2 5...

Страница 5: ...meeste medische centra gebruiken toestellen die gevoelig zijn voor externe radiofrequente stralen Gebruik uw PMR daarom niet in medische centra om elektromagnetische storingen te vermijden Wrijf het...

Страница 6: ...quement pour emploi dans les pays suivants Autriche Belgique Bulgarie Chypre Danemark Estonie Finlande France Allemagne Gr ce Hongrie Islande Irlande Italie Lettonie R publique tch que Lituanie Luxemb...

Страница 7: ...la fin de la transmission Call d Envoyer un message Pressez le bouton PTT fig 1 2 et gardez le Parlez dans le micro d une distance de 2 5 5cm Quand vous avez termin rel chez le bouton PTT pour pouvoi...

Страница 8: ...nimum est de 2 m tres Les 2 PMR sont trop loign s ou des obstacles perturbent la connexion Sans objets perturbant la port e est de 3 kilom tres environ Toutes les informations pr sent es dans ce manue...

Страница 9: ...las pilas a la vez No mezcle pilas nuevas agotadas y pilas de diferentes tipos o capacidades No mezcle pilas recargables y no recargables Opcional est n disponibles un adaptador y pilas recargables c...

Страница 10: ...las pilas El PMR3 ha sido ajustado en la f brica No abra la caja y no modifique los ajustes El usuario s lo puede reemplazar las pilas Mantenga el PMR3 alejado de polvo humedad o temperaturas extrema...

Страница 11: ...eltvorschriften Falls Zweifel bestehen wenden Sie sich f r Entsorgungsrichtlinien an Ihre rtliche Beh rde Wir danken Ihnen f r den Kauf des PMR3 Bei diesem Ger t wird einen Ohrh rer mit Mikrofon der a...

Страница 12: ...ingestellt ist b Kanal ausw hlen Dr cken Sie auf auf Abb 1 4 oder ab Abb 1 11 zur Auswahl des Kanals Setzen Sie zur Kommunikation die beiden Ger te auf denselben Kanal c Aufruf Funktion Call Dr cken S...

Страница 13: ...chaltet nicht ein Pr fen Sie die Polarit t der Batterien oder f hren Sie einen Batteriewechsel durch Die Nachricht kommt nicht durch Dr cken Sie die PTT Taste v llig w hrend Sie sprechen Pr fen Sie di...

Страница 14: ...n commerciale Emetteur r cepteur 446MHz Markenname PMR Funkger t 446MHz denominaci n comercial Transmisor receptor PMR 446MHz type or model type of model type ou mod le Typ oder Modell tipo o modelo P...

Страница 15: ...Les donn es techniques sont disponibles et peuvent tre obtenues chez Technische gegevens zijn beschikbaar en kunnen worden aangevraagd bij Die technische Dokumentation zu den oben gennanten Produkten...

Отзывы: