CTC1000
V. 04 – 11/02/2016
36
©Velleman nv
2222
Programmed user code
11
DTMF command
00
to receive confirmation message
Confirmation message
A confirmation SMS message will read on your mobile phone as:
Confirmed
MICHAEL 2222 11 00
USER1 Arm
Send the SMS message to command the Unit to enter Arm Mode without a confirmation SMS back to your
mobile phone. The format is
9999
SMS keyword
5678
Programmed user code
11
DTMF command
The system will automatically filter through all incoming SMS messages for SMS Keyword and automatically
ignores and deletes SMS which does not contain the SMS keyword. For all authorized remote command that
comes with proper keyword and pin code, the system will immediately carry out the contained command(s) and
delete the SMS message afterward.
16.
System reset
When resetting the control panel, all programmed parameters (including pin codes) are reset to factory defaults
and all devices are removed. You have to do the programming and add the devices one by one again.
The control panel can clear all programmed parameters by the following sequence:
1.
Remove the power supply and remove the backup battery.
2.
Apply power while holding down the
key.
3.
Release the
key when you hear a tone.
The control panel will display Enter Code.
4.
Enter the following key sequence:
, OK key
5.
Press OK.
If you enter an incorrect key, the unit will revert to normal Alarm On mode.
17.
Entering text
The keypad can be used to enter text for user names, zone names, SMS texts…
•
Locate the numeric key displaying the letter or symbol you want to enter and press it repeatedly until the
letter or symbol appears.
•
Release the key and the flashing cursor automatically jumps to the next position for you to continue with
the next letter by the same method.
18.
Technical Specifications
power supply
100-240 Vac/50-60 Hz - 12 Vdc 500 mA (adapter incl.)
back-up battery
7.2 V 600 mAh Ni-Mh rechargeable battery (incl.)
battery back-up time
± 8 hours
sound level
± 104 dB @ 1m
frequency
868.6375 MHz
operating temperature
-10 to +45 °C
humidity
up to 90 % non-condensing
dimensions
185 x 120 x 26 mm
weight
420 g
Содержание CTC1000
Страница 2: ...CTC1000 V 04 11 02 2016 2 Velleman nv...