CTC1000
V. 04 – 11/02/2016
34
©Velleman nv
2.
The screen will display
Fault Dsp
Arm
with the cursor next to Fault Dsp.
3.
Press OK key to select Fault Dsp.
All the errors are listed.
4.
Use the
&
keys to move the cursor up or down.
5.
After viewing all the errors, press
key, a prompt message is displayed.
Clear Fault
Dsp (OK?)
6.
If the error has been corrected, press OK.
The error will be cleared and the screen returns to Alarm off.
Notes
•
If the error has not been corrected, the display will not be cleared. It will appear again while you try to arm
the system and the error prevents the system from being armed. The error display can be cleared only
after the error has been corrected.
•
Even when the error message is cleared, the error will still be retained in the log.
14.2
Error Response
•
When an error is detected, in addition to the error display, the control panel will also respond depending on
the nature of the event.
•
Except for sabotage alarms, the control panel and external sirens will not sound audible siren for error.
•
In all modes, when Panel AC power failure or tamper trigger happens, the control panel will send error
reports by SMS. For all other errors, the control panel will NOT send error report by SMS.
AC Power fail
•
The yellow LED will light and the error message will be
displayed.
•
The panel will report the error by SMS to the first telephone
number in all modes within 15-30 minutes.
•
Once AC Power is restored, the panel also will report the restore
event by SMS to the first telephone number within 15-30
minutes.
control panel low battery
•
Any time the system detects battery Low on the panel, yellow
LED will light while this error message can be viewed on LCD
under Fault Display.
•
When control panel is powered by an AC adapter, the control
panel is incapable of detecting low battery condition.
sensor low battery
•
If the low battery is detected on any sensor, yellow LED will light
up at any time. The error message can be viewed on LCD under
Fault Display in the user menu.
panel sabotaged
•
If the Tamper switch on the control panel is triggered, yellow
LED will light. The error message can be viewed on LCD under
Fault Display in the user menu.
•
In addition, the panel will report the error by SMS to the first
telephone number in all modes.
sensor sabotaged
•
If the tamper switch on the PIR sensor, door contact, remote
keypad, or outdoor siren is triggered, the yellow LED will light.
The error message can be viewed on LCD under Fault Display in
the user menu.
•
In addition, the panel will report the error by SMS to the first
telephone number in all modes.
•
The siren will sound alarm for tamper-trigger according to the
Tamper Alarm setting (see section Tamper Alarm in chapter 8).
sensor out-of-order
•
When the control panel has not received the supervisory signal
from each individual PIR sensor or door contact, etc. for a period
(according to the setting of the Supervision), the yellow LED on
Содержание CTC1000