CTC1000
V. 04 – 11/02/2016
35
©Velleman nv
the panel will light while this error message can be viewed on
LCD under Fault Display. No alarm event will be reported.
interference
•
When the system is programmed with Interference detection ON
and when there is an interference detected for 30 seconds, the
yellow LED will light up. The error message can be viewed on
LCD under Fault Display in the user menu.
14.3
Error messages
The error message is displayed in short form as below:
Message displayed
Meaning
AC failure
AC Power Fail
GSM Signal
GSM out of signal
Interference
interference detected
Panel L.B.
low battery on the control panel
Panel Tamper
sabotage on the control panel
(Sensor w/ Zone Name) + L.B.
low battery on the sensor
(Sensor w/ Zone Name) + out
sensor out-of-order
(Sensor w/ Zone Name) + Tamper
sabotage on a sensor
Sim Card?
SIM card missing
Example
: the message DC Z 01 L.B. means Zone 1 Door Contact is low battery.
Note
While you arm the system, if any of door contact or PIR is triggered, arming is also prohibited and the sensor
triggered will be displayed as error message.
Message displayed
Meaning
(DC w/ Zone Name) + open
Door Contact triggered
(IR w/ Zone Name) + Active
PIR triggered
15.
Remote commanding via SMS message
The unit can be controlled by remote control commands sent via sms messages.
Remember to change the Language setting of your mobile phone to English before proceeding.
SMS Remote Control Command Table
Control Command
Action
00
hang up with Confirmation
10
disarm
11
arm
20
UR#1 deactivated
21
UR#1 activated
30
UR#2 deactivated
31
UR#2 activated
For 2-digit Remote Control Command
Send the SMS message to command the Unit to enter Arm Mode and send a confirmation SMS back to your
mobile phone. The format is:
MICHAEL 2222 11 00
MICHAEL
SMS keyword
Содержание CTC1000