CAMCOLD17
15/05/2009
©2008 Velleman
®
Components nv
4
•
Be very careful not to touch any other part inside the housing while setting the switches, as damage
might occur.
•
D1~D7 are used to set the ID of the device, allowing for a system with up to 64 unique devices. Refer
to the table below (
Θ
indicates dipswitch in the ON-position).
•
The devices can be controlled using a Pelco controller (not included, e.g. CAMCOLSD1C, CAMCOLD/CK)
or a DVR (not included, e.g. DVR4MQAEE, DVR4H, 3GSYSTEM, DVR8N2).
Note:
when using an IR remote control device (not included, e.g. CAMCOLD17RC), only the 9 first
(lowest) IDs can be controlled.
ID D7 D6 D5 D4 D3 D2 D1 ID D7 D6 D5 D4 D3 D2 D1
01
Θ
33
Θ
Θ
02
Θ
34
Θ
Θ
03
Θ
Θ
35
Θ
Θ
Θ
04
Θ
36
Θ
Θ
05
Θ
Θ
37
Θ
Θ
Θ
06
Θ
Θ
38
Θ
Θ
Θ
07
Θ
Θ
Θ
39
Θ
Θ
Θ
Θ
08
Θ
40
Θ
Θ
09
Θ
Θ
41
Θ
Θ
Θ
10
Θ
Θ
42
Θ
Θ
Θ
11
Θ
Θ
Θ
43
Θ
Θ
Θ
Θ
12
Θ
Θ
44
Θ
Θ
Θ
13
Θ
Θ
Θ
45
Θ
Θ
Θ
Θ
14
Θ
Θ
Θ
46
Θ
Θ
Θ
Θ
15
Θ
Θ
Θ
Θ
47
Θ
Θ
Θ
Θ
Θ
16
Θ
48
Θ
Θ
17
Θ
Θ
49
Θ
Θ
Θ
18
Θ
Θ
50
Θ
Θ
Θ
19
Θ
Θ
Θ
51
Θ
Θ
Θ
Θ
20
Θ
Θ
52
Θ
Θ
Θ
21
Θ
Θ
Θ
53
Θ
Θ
Θ
Θ
22
Θ
Θ
Θ
54
Θ
Θ
Θ
Θ
23
Θ
Θ
Θ
Θ
55
Θ
Θ
Θ
Θ
Θ
24
Θ
Θ
56
Θ
Θ
Θ
25
Θ
Θ
Θ
57
Θ
Θ
Θ
Θ
26
Θ
Θ
Θ
58
Θ
Θ
Θ
Θ
27
Θ
Θ
Θ
Θ
59
Θ
Θ
Θ
Θ
Θ
28
Θ
Θ
Θ
60
Θ
Θ
Θ
Θ
29
Θ
Θ
Θ
Θ
61
Θ
Θ
Θ
Θ
Θ
30
Θ
Θ
Θ
Θ
62
Θ
Θ
Θ
Θ
Θ
31
Θ
Θ
Θ
Θ
Θ
63
Θ
Θ
Θ
Θ
Θ
Θ
32
Θ
64
Θ
•
D8:
Baud rate:
ON = 4800bps; OFF = 2400bps
•
D9:
Protocol:
ON = PELCO_P protocol; OFF = PELCO_D protocol
•
D10:
Termination:
ON = 120
Ω
terminal resistor; OFF = high resistor
Note:
1 camera must terminate the databus with a 120
Ω
resistor; all other cameras on the databus
must have a high input resistor.
Factory settings:
PELCO_D, 2400bps, ID #01
D10 D9 D8 D7 D6 D5 D4 D3 D2 D1
Θ
Θ