EN
-29-
Connect the device's cold water
line (marked with the arrow) to the
water inlet tap, the hot water line
(marked with the arrow) to the
water outlet record.
During connection, use 1/2 "seals
which are supplied with the device,
one at each end and perform the tightening with a suitable key. Use the
arrows to check the correctness of the connection directions. The arrows
should be pointing outwards in the water inlet direction and inward (in the
same direction as the water flow) in the water outlet direction.
The water inlet pipe of the device is elastic steel connection and can be
easily hand shaped according to the mounting conditions. The water outlet
pipe is made of soft copper and can be shaped by hand or by means of a
pliers without damaging the pipe according to the mounting conditions.
Open the water valve to let the water go to the device and taps and check
for leaks at the connections. Then open and close the hot water tap a few
times to clear any air gaps that may occur from the system and the device.
Take the air of the sudden water heater:
Open the hot water tap for this
and rinse the device for 1 minute until no more bubbles come out.
Electrical Connection (By a Qualified Technician Only):
Attention please!
The electrical connection must be made according to national regulations
or local ordinances set by the local electricity distribution company. The
electric spark heater is a device with a protection class I and must be
connected to a protective earth line! All water connections must be
completed before the electrical connections are made!