Veikong VK100 0R2G1 Скачать руководство пользователя страница 22

 

22

 / 

24

 

 

a) Adjust the orientation of photovoltaic array. 

b) Check if the output currents of all groups of photovoltaic array are consistent and 

remove the connection faults. 

 

7.5 The water pump is operated but the operation frequency is too small or the water 

yield is less or even unavailable. 

Phenomenon:   

After this  Inverter starts the output, the water pump can be operated but the output 

frequency, sunlight and components are less than the preset one. The water yield is 

less or even unavailable. 

Cause: 

a) The photovoltaic battery array does not point to the sun and the output power of it 

is insufficient. 

b)  Fault  happens  to  the  connection  of  photovoltaic  battery  array,  one  or  several 

groups  of  photovoltaic  battery  array  have  no  output  and  the  output  power  of 

photovoltaic battery array is insufficient. 

Check focus and countermeasures: 

a) Adjust the orientation of photovoltaic battery array. 

b)  Check  if  the  output  currents  of  all  groups  of  photovoltaic  battery  array  are 

consistent and remove the connection faults. 

 

7.6 This Inverter can be started but the water pump does not operate.  

Phenomenon:   

This Inverter can be displayed normally. 

Cause: 

a) This Inverter has no output. 

b) Water pump is damaged or fault happens to the output line. 

Check focus and countermeasures: 

a) Shut it down and cut off the input power of this Inverter, dismantle the line of water 

pump, turn on this Inverter again and check if the output of this Inverter is normal.  

Содержание VK100 0R2G1

Страница 1: ...VK100 Series Smart Single Phase Solar inverter User Manual...

Страница 2: ...ump Solar photovoltaic battery array means transmitting the solar radiation energy into DC electric energy which is adjusted by the photovoltaic pump inverter The solar panel nonlinear DC power is tra...

Страница 3: ...ical management of desert and barren mountain supply of clean domestic water for both humans and livestock municipal sewerage treatment landscape fountain of urban square water conservancy facilities...

Страница 4: ...ion of solar photovoltaic battery array power configured according to the requirements for water withdrawal on site the model and power of the water pump shall be determined according to the hydraulic...

Страница 5: ...s provided with soft start function and is free from impact current so that it can remove water hammer totally It shall be configured with the battery panel with small power which can reduce the costs...

Страница 6: ...amiliar with the high voltage line and electrical hazards shall be liable for the installation and check of this Inverter The hazards caused by incorrect operation may cause serious injury or even dea...

Страница 7: ...ble 5 Never install this Inverter outdoors directly since it shall avoid direct sunshine It is not allowed to start stop the motor with contactor without consulting the manufacturer The internal power...

Страница 8: ...gap which is no shorter than 15cm shall be left on the top and at the bottom of this Inverter 2 Sufficient space shall be left surrounding this Inverter so as to facilitate maintenance 3 Please use th...

Страница 9: ...e isolation switch between the power and this Inverter shall be set If the wire noise or instantaneous voltage becomes too large isolation transformer or wire reactor can be used to provide this Inver...

Страница 10: ...ilter at the output side of this Inverter since this will damage this Inverter It also may damage the capacitor and surge filter 6 The load other than single phase squirrel cage motor is prohibited Th...

Страница 11: ...solar panels is connected with L1 L and L2 N If it is solar and power automatic switching models then connected with P and P terminals and single phase 230V AC power is connected with L1 L and L2 N te...

Страница 12: ...drainage water level sensor LW Control terminal Input of detection signal of supply water level sensor COM Control terminal COM is the public terminal of all control terminals Reserved input terminal...

Страница 13: ...ical sensor RA and RB are a pair of normally open contacts of the relay the overload capacity of contact 1A 230VAC It is connected after the operation of this Inverter 3 0 Panel and Operation Instruct...

Страница 14: ...he detection of water level The output of water level detection sensor of water pump is disconnected LL means valid connection The output of overflow sensor of water pump is connected HH means valid d...

Страница 15: ...own key at the same time after water level alarming occurs 4 0 Parameters The parameters that may need adjusting in installation and usage are shown in the table below No Parameters Parameter function...

Страница 16: ...the table are the factory parameters which shall not be adjusted arbitrarily unless the factory informs it clearly If LL or OF alarming happens to this Inverter it can not be started again until the...

Страница 17: ...h the requirements Check if the water pump inverter satisfies the installation and connection requirements Check if the water pump and pipeline satisfy the operation requirements Adjust the photovolta...

Страница 18: ...y the following factors Too small power output by solar battery array Unreasonable design of photovoltaic pump system 6 0 Automatic Operation After the equipment is installed and connected and the inv...

Страница 19: ...gy and electric supply the electric supply will be used automatically if the power of solar photovoltaic battery is not enough to drive the water pump to yield water If however the power of the photov...

Страница 20: ...evel sensor of water supply works b The output type parameter F XX of water level sensor of water supply is set by mistake c The water pump is under restart delay status Check focus and countermeasure...

Страница 21: ...to connect optical sensor or short circuit terminal PR1 and PR2 Check focus and countermeasures a This Inverter is under automatic working mode b By reducing the value of the starting voltage c By co...

Страница 22: ...to the connection of photovoltaic battery array one or several groups of photovoltaic battery array have no output and the output power of photovoltaic battery array is insufficient Check focus and c...

Страница 23: ...this Inverter b Abnormal internal detection protection line of this Inverter c Abnormal water pump Check focus and countermeasures a Configure the matched power of the water pump or this Inverter cor...

Страница 24: ...ltage AC230V 1 PHASE Scope of output frequency 0 50 60Hz Cooling mode Forced air cooling Service environment Capacity can be reduced if above 10 50 Altitude 1000 m or below Weight kg 1 6 1 8 1 8 2 2 2...

Отзывы: