19

 / 

24

 

 

photovoltaic  power  input  satisfies  the  water  outlet  conditions;  otherwise,  it  will  keep 

waiting or switch to the mains supply for operation automatically. 

Note:  The  power  switch  shall  be  also  connected  during  the  process  of  automatic 

operation and the input end of the solar photovoltaic battery will turn on automatically 

after the sunrise. The water pump can operate automatically as long as the operation 

conditions  can  be  satisfied.  This  Inverter  will  restart  to  operate  again  if  the  starting 

conditions  can  be  met  even  if  by  pressing  “RUN/STOP”  key  on  the  panel  under 

automatic mode to shut it down.

 

                              As  for  the  machine  that  can  switch  between  solar  energy  and 

electric  supply,  the  electric  supply  will  be  used  automatically  if  the  power  of  solar 

photovoltaic battery is not enough to drive the water pump to yield water. If, however, 

the  power  of  the  photovoltaic  battery  is  able  to  satisfy  the  yielding  requirements  of 

water  pump  when  the  electric  supply  is  used,  this  Inverter  will  switch  to  the  solar 

battery automatically. In other words, the solar battery shall be prioritized. In this way, 

the utilization rate of solar battery becomes higher  and the water pump can work in 

the daytime and at night without battery. It reduces the system costs and expands the 

application scope of water pump.

 

 

It  is  prohibited  to  shut  down  the water  pump  by  disconnecting  the 

inverter  input  when  the  pump  is  operated.  Instead,  cut  off  the  inverter  input 

after this Inverter stops output; otherwise, it is easy to damage this Inverter. 

 

 

Содержание VK100 0R2G1

Страница 1: ...VK100 Series Smart Single Phase Solar inverter User Manual...

Страница 2: ...ump Solar photovoltaic battery array means transmitting the solar radiation energy into DC electric energy which is adjusted by the photovoltaic pump inverter The solar panel nonlinear DC power is tra...

Страница 3: ...ical management of desert and barren mountain supply of clean domestic water for both humans and livestock municipal sewerage treatment landscape fountain of urban square water conservancy facilities...

Страница 4: ...ion of solar photovoltaic battery array power configured according to the requirements for water withdrawal on site the model and power of the water pump shall be determined according to the hydraulic...

Страница 5: ...s provided with soft start function and is free from impact current so that it can remove water hammer totally It shall be configured with the battery panel with small power which can reduce the costs...

Страница 6: ...amiliar with the high voltage line and electrical hazards shall be liable for the installation and check of this Inverter The hazards caused by incorrect operation may cause serious injury or even dea...

Страница 7: ...ble 5 Never install this Inverter outdoors directly since it shall avoid direct sunshine It is not allowed to start stop the motor with contactor without consulting the manufacturer The internal power...

Страница 8: ...gap which is no shorter than 15cm shall be left on the top and at the bottom of this Inverter 2 Sufficient space shall be left surrounding this Inverter so as to facilitate maintenance 3 Please use th...

Страница 9: ...e isolation switch between the power and this Inverter shall be set If the wire noise or instantaneous voltage becomes too large isolation transformer or wire reactor can be used to provide this Inver...

Страница 10: ...ilter at the output side of this Inverter since this will damage this Inverter It also may damage the capacitor and surge filter 6 The load other than single phase squirrel cage motor is prohibited Th...

Страница 11: ...solar panels is connected with L1 L and L2 N If it is solar and power automatic switching models then connected with P and P terminals and single phase 230V AC power is connected with L1 L and L2 N te...

Страница 12: ...drainage water level sensor LW Control terminal Input of detection signal of supply water level sensor COM Control terminal COM is the public terminal of all control terminals Reserved input terminal...

Страница 13: ...ical sensor RA and RB are a pair of normally open contacts of the relay the overload capacity of contact 1A 230VAC It is connected after the operation of this Inverter 3 0 Panel and Operation Instruct...

Страница 14: ...he detection of water level The output of water level detection sensor of water pump is disconnected LL means valid connection The output of overflow sensor of water pump is connected HH means valid d...

Страница 15: ...own key at the same time after water level alarming occurs 4 0 Parameters The parameters that may need adjusting in installation and usage are shown in the table below No Parameters Parameter function...

Страница 16: ...the table are the factory parameters which shall not be adjusted arbitrarily unless the factory informs it clearly If LL or OF alarming happens to this Inverter it can not be started again until the...

Страница 17: ...h the requirements Check if the water pump inverter satisfies the installation and connection requirements Check if the water pump and pipeline satisfy the operation requirements Adjust the photovolta...

Страница 18: ...y the following factors Too small power output by solar battery array Unreasonable design of photovoltaic pump system 6 0 Automatic Operation After the equipment is installed and connected and the inv...

Страница 19: ...gy and electric supply the electric supply will be used automatically if the power of solar photovoltaic battery is not enough to drive the water pump to yield water If however the power of the photov...

Страница 20: ...evel sensor of water supply works b The output type parameter F XX of water level sensor of water supply is set by mistake c The water pump is under restart delay status Check focus and countermeasure...

Страница 21: ...to connect optical sensor or short circuit terminal PR1 and PR2 Check focus and countermeasures a This Inverter is under automatic working mode b By reducing the value of the starting voltage c By co...

Страница 22: ...to the connection of photovoltaic battery array one or several groups of photovoltaic battery array have no output and the output power of photovoltaic battery array is insufficient Check focus and c...

Страница 23: ...this Inverter b Abnormal internal detection protection line of this Inverter c Abnormal water pump Check focus and countermeasures a Configure the matched power of the water pump or this Inverter cor...

Страница 24: ...ltage AC230V 1 PHASE Scope of output frequency 0 50 60Hz Cooling mode Forced air cooling Service environment Capacity can be reduced if above 10 50 Altitude 1000 m or below Weight kg 1 6 1 8 1 8 2 2 2...