15
/
24
Operating Instruction of Keyboard
Selection of monitoring interface:
Parameter settings and modification
The water pump can be started in the delay time set after the water level alarming
occurs under general circumstances. It is unnecessary to wait by pressing up/down
key at the same time after water level alarming occurs.
4.0 Parameters
The parameters that may need adjusting in installation and usage are shown in the
table below:
No.
Parameters
Parameter functions
Scope of setting
Delivery
value
1
CXXX
Lower limit of MPPT
voltage
DC180~300V
230V
2
HXXX
Starting voltage
DC260~360V
280V
3
P XX
Delayed starting
time after water
level alarming
4~80min
30min
4
F XX
Output type of water
level sensor of water
HH: normally
opened, LL:
HH