1 Technical specification
VFD700 Solar pump inverter user manual 3
Table 1-2 220V rating data
Drive model
Max DC input
current (A)
Rated output current
(A)
Applicable water pump
(KW)
VFD700-PV-20T00075
6.7
4.5
0.75
VFD700-PV-20T00150
9.9
7
1.5
VFD700-PV-20T00220
14.1
10
2.2
VFD700-PV-20T00400
22.6
16
4
Noted: when the output voltage is 220V, the output current will be rated value
1.4 Electrical Specifications
Table 1-3 Electrical Specifications
220V
380V
Max input DC voltage
415V
810V
Recommended MPPT voltage range
150~330VDC
270~750VDC
Recommended input voltage
310V
530V
MPPT efficiency
>99%
Input channel
2
Rated output voltage
3-phase 220VAC
3-phase 380VAC
Output frequency range
0~60Hz
Max efficiency of the machine
97%
Ambient temperature range
-10 °C~50 °C, derating if the temperature is above 40 °C
Cooling method
Air cooling
Protection degree
IP20
Altitude
Below 1000m; above 1% for every additional 100m.
Standard
CE