AC310 Series Frequency AC Drive Manual
43
F14.23
(0x0E17)
PLC 8th stage running
time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 8h stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.24
(0x0E18)
PLC 9th stage running
time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 9th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.25
(0x0E19)
PLC 10th stage
running time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 10th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.26
(0x0E1A)
PLC11th stage running
time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 11th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.27
(0x0E1B)
PLC 12th stage
running time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 12th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.28
(0x0E1C)
PLC 13th stage
running time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 13th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.29
(0x0E1D)
PLC 14th stage
running time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 14th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.30
(0x0E1E)
PLC 15th stage
running time
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC 15th stage running time
10.0
(0.0
~
6500.0(s/m/h))
RUN
F14.31~F14.45
:
PLC Operation Direction and Time Selection
Parameter
(
Address
)
Name
Content
Factory default
(range)
Adjustable
properly
F14.31
(0x0E1F)
PLC direction and
acceleration and
deceleration time of 1st
stage
V/F SVC FVC PMVF PMSVC PMFVC
Unitt: The running direction of this segment (compared with the
running command)
0: same direction 1: reverse
Ten digits: acceleration and deceleration time of this section
0: Acceleration/deceleration time 1 1: Acceleration/deceleration time
2
2: Acceleration/deceleration time 3 3: Acceleration/deceleration time
4
0000
(0000~0031)
RUN
F14.32
(0x0E20)
PLC direction and
acceleration and
deceleration time of
2nd stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.33
(0x0E21)
PLC direction and
acceleration and
deceleration time of 3rd
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.34
(0x0E22)
PLC direction and
acceleration and
deceleration time of 4th
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.35
(0x0E23)
PLC direction and
acceleration and
deceleration time of 5th
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.36
(0x0E24)
PLC direction and
acceleration and
deceleration time of 6th
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.37
(0x0E25)
PLC direction and
acceleration and
deceleration time of 7th
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.38
(0x0E26)
PLC direction and
acceleration and
deceleration time of 8th
stage
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN
F14.39
(0x0E27)
PLC direction and
acceleration and
V/F SVC FVC PMVF PMSVC PMFVC
The same settings as F14.31
0000
(0000~0031)
RUN