AC310 Series Frequency AC Drive Manual
39
6
:
1Mbps
F12.5x
:
EX-A,EX-B Communication
Parameter
(
Address
)
Name
Content
Factory default
(range)
Adjustable
properly
F12.50
(0x0C32)
Expansion port
communication
disconnection
processing
V/F SVC FVC PMVF PMSVC PMFVC
Unit: EX-A port disconnection action mode
0: No detection 1: Alarm and free stop 2: Warning and continue to
run
Ten digits: EX-B port disconnection action mode
0: No detection 1: Alarm and free stop 2: Warning and continue to
run
0000
(0000~0022)
RUN
F12.51
(0x0C33)
Expansion port EX-A
parameter update
V/F SVC FVC PMVF PMSVC PMFVC
0: No update 1: The initial value has been updated after power-on
2: Expansion port EX-A parameter recovery initial value
0
(0 ~ 2)
RUN
F12.52
(0x0C34)
Expansion port EX-B
parameter update
V/F SVC FVC PMVF PMSVC PMFVC
0: No update 1: The initial value has been updated after power-on
2: Expansion port EX-n parameter recovery initial value
0
(0 ~ 2)
RUN
F12.53
(0x0C35)
Expansion port EX-A
monitoring frame
address group 1
V/F SVC FVC PMVF PMSVC PMFVC
Ten digits: the lower address is 8 digits 00 to 63
Hundreds of thousands: address high 8 bits 00 ~ 07
0001
(0000 ~ 0763)
RUN
F12.54
(0x0C36)
Expansion port EX-A
monitoring frame
address group 2
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0002
(0000 ~ 0763)
RUN
F12.55
(0x0C37)
Expansion port EX-A
monitoring frame
address group 3
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0007
(0000 ~ 0763)
RUN
F12.56
(0x0C38)
Expansion port EX-A
monitoring frame
address group 4
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0011
(0000 ~ 0763)
RUN
F12.57
(0x0C39)
Expansion port EX-B
monitoring frame
address group 1
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0001
(0000 ~ 0763)
RUN
F12.58
(0x0C3A)
Expansion port EX-B
monitoring frame
address group 2
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0002
(0000 ~ 0763)
RUN
F12.59
(0x0C3B)
Expansion port EX-B
monitoring frame
address group 3
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0007
(0000 ~ 0763)
RUN
F12.60
(0x0C3C)
Expansion port EX-B
monitoring frame
address group 4
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
0011
(0000 ~ 0763)
RUN
4.16
F13
:
Process PID Control
F13.00-F13.06: PID given and feedback
Parameter
(
Address
)
Name
Content
Factory default
(range)
Adjustable
properly
F13.00
(0x0D00)
PID controller given
signal source
V/F SVC FVC PMVF PMSVC PMFVC
0: Keyboard digital PID given 1: Keyboard analog potentiometer
given
2: Current/voltage analog AI1 given
3: Current/voltage analog AI2 given
4: Reserved 5: Terminal pulse PUL given
6: RS485 communication reference 7: Option card
8: Terminal selection 9: Communication given active current
0
(0 ~ 9)
RUN
F13.01
(0x0D01)
Keyboard digital PID
given / feedback
V/F SVC FVC PMVF PMSVC PMFVC
Set keyboard digital PID given / feedback value
50.0%
(0.00
~
100.0%)
RUN
F13.02
(0x0D02)
PID given change time
V/F SVC FVC PMVF PMSVC PMFVC
Set the PID given change time
1.00s
(0.00
~
60.00s)
RUN