39
FC.17
PLC 2nd Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC11
FC.18
PLC 3rd Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC12
FC.19
PLC 4th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC13
FC.20
PLC 5th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC14
FC.21
PLC 6th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC15
FC.22
PLC 7th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC16
FC.23
PLC 8th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC17
FC.24
PLC 9th Step running
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC18
FC.25
PLC 10th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC19
FC.26
PLC 11th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC1A
FC.27
PLC 12th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC1B
FC.28
PLC 13th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC1C
FC.29
PLC 14th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC1D
FC.30
PLC 15th Step running
time
0.0(s/m/h)
~
6500.0(s/m/h)
10.0
●
0xC1E
FC.31
PLC 1
st
-15th Step
direction and ADD/DEC
time
LED “0” digit: current step run
direction
0: FWD
1: REV
LED “00” digit: ACC/DEC time in
this step
0: ACC/DEC time 1
1: ACC/DEC time 2
2: ACC/DEC time 3
4: ACC/DEC time 4
LED “000” digit: reserved
LED “0000” digit: reserved
0000
●
0xC1F
FC.32
0000
●
0xC20
FC.33
0000
●
0xC21
FC.34
0000
●
0xC22
FC.35
0000
●
0xC23
FC.36
0000
●
0xC24
FC.37
0000
●
0xC25
FC.38
0000
●
0xC26
FC.39
0000
●
0xC27
FC.40
0000
●
0xC28
FC.41
0000
●
0xC29
FC.42
0000
●
0xC2A
FC.43
0000
●
0xC2B
FC.44
0000
●
0xC2C
FC.45
0000
●
0xC2D
FC.46-FC.48
Reserved
0xC2E
FC.49
Swing frequency control
0: invalid 1:valid
0
●
0xC31
FC.50
Swing frequency
amplitude control
0:Relative to central frequency
1:Relative to max frequency
0
●
0xC32
FC.51
Reserved
0xC33