AC200 Frequency Inverter Maunal
10
●
Auxiliary Terminal Output Capacity
Terminal
Function Definition
Max Output
+10V
10V auxiliary power supply output, constitutes
loop with GND.
50mA
A01/A02
Analog monitor output, constitutes loop with
GND.
Max output 2mA as frequency,
voltage signal,
+24V
24V auxiliary power supply output, constitutes
loop with COM.
100mA
Y
Collector open circuit output; can set the
action-object by program.
DC24V/50mA
TA1/TB1/TC1
TA2/TB2/TC2
Passive connector output; can set the
action-object by program.
3A/240VAC
5A/30VDC
●
Connection Function Specification of Switch Terminals
Switch Terminal
Selecting Position
Function Specification
S1
K1
AO1:0 mA
~
20mA or 4 mA
~
20mA current output
K2
AO1:0V
~
10V voltage output
S2
K3
AI:0 mA
~
20mA or 4 mA
~
20mA input current
K4
AI: 0V
~
10V input voltage
S3
K5
AO2: 0.0 kHz
~
100kHz (J1 on), open collector circuit output
K6
AO2:0.0 kHz
~
100kHz (J1 on), active source output
S4
K7
RS485: connect with 120Ω terminal resistor
K8
RS485:connect without 120Ω terminal resistor
S5
J1
AO2:0.0 kHz
~
100kHz frequency output
J2
AO2:0 mA
~
20mA or 4 mA
~
20mA current output
J3
0 V
~
10V voltage output
S6
+24V
Short +24V terminal and PLC terminal
PLC
PLC terminal receiving external power input
COM
Short PLC terminal and COM terminal
S7
K9
Disconnect GND terminal and PE discharge loop
K10
Connect GND terminal and PE discharge loop
AS
VS
GND
GND
AO2
AO1
X1
X2
AI
+10V
COM
TC1
PLC
TA1
A+
+24V
X7/PUL
X4
X3
X5
TB2
X6
TA2
B-
Y
TB1
COM
TC2