1 For your safety

VEGAPULS 62 • 4 … 20 mA/HART - four-wire

47121-EN-160215

1  For your safety

1.1  Authorised personnel

All operations described in this operating instructions manual must 

be carried out only by trained specialist personnel authorised by the 

plant operator.
During work on and with the device the required personal protective 

equipment must always be worn.

1.2  Appropriate use

VEGAPULS 62 is a sensor for continuous level measurement.

You can find detailed information about the area of application in 

chapter "

Product description

".

Operational reliability is ensured only if the instrument is properly 

used according to the specifications in the operating instructions 

manual as well as possible supplementary instructions.

1.3  Warning about incorrect use

Inappropriate or incorrect use of the instrument can give rise to 

application-specific hazards, e.g. vessel overfill or damage to system 

components through incorrect mounting or adjustment. Also the pro-

tective characteristics of the instrument can be influenced. 

1.4  General safety instructions

This is a state-of-the-art instrument complying with all prevailing 

regulations and guidelines. The instrument must only be operated in a 

technically flawless and reliable condition. The operator is responsible 

for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the 

compliance of the necessary occupational safety measures with the 

current valid rules and regulations and also take note of new regula-

tions.
The safety instructions in this operating instructions manual, the na-

tional installation standards as well as the valid safety regulations and 

accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device 

beyond that described in the operating instructions manual may be 

carried out only by personnel authorised by the manufacturer. Arbi-

trary conversions or modifications are explicitly forbidden.

The safety approval markings and safety tips on the device must also 

be observed.
Depending on the instrument version, the emitting frequencies are in 

the C, K or W band range. The low emitting frequencies are far below 

the internationally approved limit values. When used correctly, the 

device poses no danger to health.

Содержание VEGAPULS 62

Страница 1: ...Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 62 4 20 mA HART four wire Approval according to LPR radio standard Document ID 47121...

Страница 2: ...plan double chamber housing 11 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module 13 5 2 Parameter adjustment 13 6 Supplement 6 1 Technical data 19 Information T...

Страница 3: ...ctions This is a state of the art instrument complying with all prevailing regulations and guidelines The instrument must only be operated in a technically flawless and reliable condition The operator...

Страница 4: ...ts of the following NAMUR recom mendations NE 21 Electromagnetic compatibility of equipment NE 43 Signal level for malfunction information from measuring transducers NE 53 Compatibility of field devic...

Страница 5: ...sistant to interference signals including such that may cause undesired operating states of the device Modifications not expressly approved by the manufacturer will lead to expiry of the operating lic...

Страница 6: ...n class 14 ID number instrument documentation 15 Reminder to observe the instrument documentation The type label contains the serial number of the instrument With it you can find the following instrum...

Страница 7: ...elow into the vessel socket and secure it against falling off 4 Retighten the antenna with hexagon screws to the antenna socket max torque see chapter Technical data Note The radar sensor with rinsing...

Страница 8: ...t tightly 7 Check if the O ring seal is present on the connection piece and make sure it is not damaged Note A damaged O ring seal must be replaced FKM SHS FPM 70C3 GLT FFKM Kalrez 6375 8 Remount the...

Страница 9: ...s 1 Distance from the vessel wall 200 mm the antenna should protrude 10 mm into the vessel ca 10 mm 200 mm 7 87 Fig 4 Distance of the antenna to the vessel wall vessel ceiling 2 Note min socket diamet...

Страница 10: ...n Proceed as follows 1 Unscrew the housing lid 2 Loosen compression nut of the cable gland and remove blind plug 3 Remove approx 10 cm 4 in of the cable mantle signal output strip approx 1 cm 0 4 in i...

Страница 11: ...e housing lid back on The electrical connection is finished Information The terminal blocks are pluggable and can be removed from the housing insert To do this lift the terminal block with a small scr...

Страница 12: ...N 2 6 7 8 Fig 7 Connection compartment with double chamber housing with low voltage Terminal Function Polarity 1 Voltage supply L 2 Voltage supply N 5 4 20 mA output active 6 4 20 mA output passive 7...

Страница 13: ...e desired position and turn it to the right until it snaps in 3 Screw housing lid with inspection window tightly back on Disassembly is carried out in reverse order The display and adjustment module i...

Страница 14: ...eight must be carried out 100 0 0 5 m 19 68 5 m 196 9 2 1 3 Fig 9 Parameter adjustment example min max adjustment 1 Min level max measuring distance 2 Max level min measuring distance For this adjustm...

Страница 15: ...urve The following circumstances cause interfering reflections and can influence the measurement High sockets Vessel internals such as struts Agitators Buildup or welded joints on vessel walls Note A...

Страница 16: ...seful if the saved false signal suppression no longer matches the metrological conditions in the vessel Extend is used to extend an already created false signal suppres sion This is useful if a false...

Страница 17: ...age Order specific Displayed value Filling height in Backlight Switched on Menu Diagnosis Menu item Parameter Default setting Sensor status Peak value Distance Electronics tem perature Temperature Mea...

Страница 18: ...ent module VEGAPULS 62 4 20 mA HART four wire 47121 EN 160215 Menu Info Menu item Parameter Device name VEGAPULS 6 Instrument version Hardware and software version Date of manufacture Date Instrument...

Страница 19: ...NPT Material ca ble gland Material seal insert Cable diameter 4 5 8 5 mm 5 9 mm 6 12 mm 7 12 mm 10 14 mm PA NBR Brass nickel plated NBR Stainless steel NBR Wire cross section spring loaded terminals M...

Страница 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: