19
6 Supplement
VEGAPULS 62 • 4 … 20 mA/HART - four-wire
47121-EN-160215
6 Supplement
6.1 Technical data
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ
Cable entry
M20 x 1.5, ½ NPT
Ʋ
Cable gland
M20 x 1,5; ½ NPT (cable ø see below table)
Ʋ
Blind plug
M20 x 1.5; ½ NPT
Ʋ
Closing cap
½ NPT
Material ca-
ble gland
Material seal
insert
Cable diameter
4.5 … 8.5 mm
5 … 9 mm
6 … 12 mm
7 … 12 mm
10 … 14 mm
PA
NBR
–
●
●
–
●
Brass, nickel-
plated
NBR
●
●
●
–
–
Stainless
steel
NBR
–
●
●
–
●
Wire cross-section (spring-loaded terminals)
Ʋ
Massive wire, stranded wire
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ
Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Voltage supply
Operating voltage
Ʋ
Version for low voltage
9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz
Ʋ
Version for mains voltage
90 … 253 V AC, 50/60 Hz
Reverse voltage protection
Integrated
Max. power consumption
4 VA; 2.1 W