L
evel
S
witching status
S
ignal lamp
-
S
witching output
(
yellow
)
M
ode min
.
D
ry run protection
open
F
ailure of the supply
voltage
(
max
./
min
.
mode
)
any
open
M
alfunction
any
open
R
ed failure
LED
lights
D
epending on the switching function your output should carry out
,
you
can determine the switching direction by means of the slide switch
.
l
F
or maximum indication or over
fi
ll protection set the slide switch to
position max
.
l
F
or minimum indication or dry run protection
,
set the slide switch to
position min
.
T
he transistor output is closed when the yellow signal lamp lights
.
W
ith the two keys you can change the
LED
indication strip and adjust
the switching point to the medium
.
T
he keys are lowered to avoid unintentional changes of the setting
.
F
or
adjustment
,
use for example
,
a small screwdriver
.
I
f you press one of the keys for more than two seconds
,
the adjustment
range shifts automatically in the respective direction
.
T
he greater the
distance between emitting and receiving unit
,
the greater the adjust
-
ment range of the indication
.
T
he
LED
indication strip always shows a
small section of the actual measuring range
.
P
ressing the
"<
--
"
key makes the sensor more sensitive
.
P
ressing the
"
--
>"
key makes the sensor less sensitive
.
S
ensitivity adjustment
VEGAMIP R
61
• -
T
ransistor
29
6
S
etup
40694
-