52
11 Supplement
VEGACAL 69 • Two-wire 4 … 20 mA/HART
31178-EN-200929
1000
750
500
250
12
18
16
14
20
22
24
26
28
30
32
34
36
Ω
V
4
1
2
3
Fig. 31: Voltage diagram
1 HART load
2 Voltage limit Ex-ia instrument
3 Voltage limit non-Ex-/Ex-d-ia instrument
4 Operating voltage
Permissible residual ripple
Ʋ < 100 Hz
U
ss
< 1 V
Ʋ 100 Hz … 10 kHz
U
ss
< 10 mV
Load
see diagram
Potential connections and electrical separating measures in the instrument
Electronics
Not non-floating
Reference voltage
7)
500 V AC
Conductive connection
Between ground terminal and metallic process fitting
Electrical protective measures
Protection rating
Housing material
Version
IP-protection class
NEMA protection
Plastic
Single chamber
IP66/IP67
Type 4X
Double chamber
IP66/IP67
Type 4X
Aluminium
Single chamber
IP66/IP68 (0.2 bar)
IP68 (1 bar)
Type 6P
Type 6P
Double chamber
IP66/IP67
IP66/IP68 (0.2 bar)
IP68 (1 bar)
Type 4X
Type 6P
Type 6P
Stainless steel (electro-
polished)
Single chamber
IP66/IP68 (0.2 bar)
Type 6P
Stainless steel (precision
casting)
Single chamber
IP66/IP68 (0.2 bar)
IP68 (1 bar)
Type 6P
Type 6P
Double chamber
IP66/IP67
IP66/IP68 (0.2 bar)
IP68 (1 bar)
Type 4X
Type 6P
Type 6P
7)
Galvanic separation between electronics and metal housing parts
Содержание VEGACAL 69
Страница 14: ...14 4 Mounting VEGACAL 69 Two wire 4 20 mA HART 31178 EN 200929 Fig 6 Inflowing medium...
Страница 57: ...57 Notes VEGACAL 69 Two wire 4 20 mA HART 31178 EN 200929...
Страница 58: ...58 Notes VEGACAL 69 Two wire 4 20 mA HART 31178 EN 200929...
Страница 59: ...59 Notes VEGACAL 69 Two wire 4 20 mA HART 31178 EN 200929...