19
4 Mounting
VEGABAR 81 • 4
… 20 mA
45025-EN-140228
4.5 External housing
1
2
3
4
5
Fig. 13: Setup process assembly, external housing
1 Pipeline
2 Process assembly
3 Connection cable process assembly - External housing
4 External housing
5 Signal cable
1.
Mark the holes according to the following drilling template
2.
Fasten wall mounting plate with 4 screws
90 mm
(3.54")
R 3,5 mm
(0.14")
3mm
(0.12")
70 mm
(2.76")
8 mm
(0.32")
93 mm (3.66")
110 mm (4.33")
Fig. 14: Drilling template - wall mounting plate
Configuration