19
6 Supplement
VEGAPULS SR 68 • Modbus and Levelmaster protocol
47164-EN-140129
6 Supplement
6.1 Technical data
Electromechanical data - version IP 66/IP 67
Options of the cable entry
Ʋ
Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ
Cable entry
½ NPT
Ʋ
Blind plug
M20 x 1.5; ½ NPT
Ʋ
Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ
Supply and signal circuit (only with low
voltage)
M12 x 1 plug
Ʋ
Indication circuit
M12 x 1 plug
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ
Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Voltage supply
Operating voltage
8 … 30 V DC
Power consumption
< 500 mW
Interpolation protection
Integrated