T
he greater the di
ff
erence in the pulse rate between covered and
uncovered status
,
the greater the di
ff
erential value
(
D
elta
I
)
and the
more reliable the measurement
.
T
he automatically calculated damping
is also oriented around the
D
elta
I
value
.
T
he higher the value
,
the
lower the damping
.
A D
elta
I
value below
10
%
is an indication for a critical measurement
.
I
n this menu item you can simulate measured values via the current
output
.
T
his allows the signal path to be tested
,
e
.
g
.
via downstream
indicating instruments or the input card of the control system
.
N
ote
:
T
o carry out a simulation with the indicating and adjustment module
,
you have to switch on the simulation switch on the electronics module
(
switch position
1
).
Y
ou can
fi
nd the rotary switch on the electronics module in the
electronics and connection department
(
large cover
).
Y
ou can simulate di
ff
erent values
:
P
ulse rate of the sensor
S
witching function of the relay
I
nformation
:
60
minutes after the key was pressed for the last time
,
the simulation is
interrupted automatically
.
Y
ou can also interrupt the simulation with the
switch on the electronics module
.
D
iagnosis
/
S
imulation
30
POINTRAC
31
•
F
oundation
F
ieldbus
6
S
et up with the indicating and adjustment module
41779
-
EN
-
120329