lends itself well for level detection of bulk solids with
low density
.
M
ount the instrument horizontally at the height of the
requested switching point
.
M
ount the source container
VEGASOURCE
displaced by
90
°
in order
to get the widest possible radiation angle
.
W
hen the sensor is covered by the medium
,
the radiation damping is
considerably stronger
-
hence
,
the switching point is all the more
reliable
.
I
f the max
.
ambient temperature is exceeded
,
you must take suitable
measures to protect the instrument against overheating
.
Y
ou can protect the instrument by providing a suitable insulation
against the heat or mounting the instrument further away from the heat
source
.
M
ake sure these measures are taken into account already in the
planning stage
.
I
f you want to carry out such measures later on
,
contact our specialists to ensure that the accuracy of the application is
not impaired
.
I
f these measures are not su
ffi
cient to maintain the max
.
ambient
temperature
,
you could consider using the water cooling system we
o
ff
er for
POINTRAC
31
.
T
he water cooling must also be included in the calculations for the
measuring point
.
C
ontact our specialists regarding the dimensioning of
the water cooling
.
P
rotection against heat