S
hielding
-
P
rovide good shielding between the radioactive source
and yourself as well as all other persons
.
S
pecial source containers
(
e
.
g
.
VEGASOURCE
)
as well as all materials with high density
(
e
.
g
.
lead
,
iron
,
concrete
,
etc
.)
provide e
ff
ective shielding
.
T
ime
-
S
tay as short a time as possible in radiation exposed areas
.
S
ource
-
Y
our distance to the source should be as large as possible
.
T
he local dose rate of the radiation decreases in proportion to the
square of the distance to the radiation source
.
T
he plant operator must appoint a radiation safety o
ffi
cer with the
necessary expert knowledge
.
H
e is responsible that the radiation
protection ordinance is maintained and that all radiation protection
measures are implemented
.
C
ontrol areas are areas in which the local dose rate exceeds a certain
value
.
O
nly persons who undergo o
ffi
cial dose monitoring are allowed
into these control areas
.
Y
ou can
fi
nd the respectively valid limit values
for control areas in the guideline of the respective authority
(
in
G
ermany
,
for example
,
the radiation protection ordinance
).
W
e are at your disposal for further information concerning radiation
protection and regulations in other countries
.
R
adiation safety o
ffi
cer
C
ontrol area
POINTRAC
31
•
F
oundation
F
ieldbus
11
3
P
roduct description