![Vega POINTRAC 31 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/vega/pointrac-31/pointrac-31_operating-instructions-manual_3829165013.webp)
Y
ou must follow the instructions of this
"
S
ource
S
izing
"
document in
addition to the following mounting instructions
.
T
he following mounting information is applicable as long as there is
nothing else speci
fi
ed in the
"
S
ource
S
izing
"
document
.
2
1
F
ig
.
3
:
M
ounting position
-
level detection
1
M
ounting vertically
2
M
ounting horizontally
,
at right angles to container
Y
ou can
fi
nd information on protective barriers and the mounting of the
corresponding source container in the operating instructions manual of
the source container
,
e
.
g
.
VEGASOURCE
.
F
or level detection
,
the sensor is generally mounted horizontally at the
height of the requested limit level
.
M
ake sure that there are no struts or
reinforcements at this position in the vessel
.
D
irect the exit beam of the source container exactly towards the
measuring range of
POINTRAC
31
.
F
asten the sensor in such a way that it cannot fall out of the holder
.
I
f
necessary
,
provide the sensor with a support from below
.
M
ount the source container and
POINTRAC
31
as close as possible to
the vessel
.
I
f there are gaps
,
secure the area with a safety fence and
protective grating so that no one can reach into the dangerous area
.
POINTRAC
31
•
F
oundation
F
ieldbus
13
4
M
ounting
41779
-
EN
-
120329