Principle of operation
The gauge receives a shaped or collimated beam of radiation from the
source holder through the process material. The material in the vessel
shields part of the detector from exposure to the radiation field. As the
process material mass decreases, the detector senses more radiation, and
vice versa.
Calibrating the gauge associates the detector readings (or counts) with the
density of the material in engineering units. The output range of the gauge is
a 4 mA ... 20 mA current loop signal, in proportion to the density of the
process.
System overview
The gauge uses VEGA’s GEN2000
®
, VEGA’s newest compact electronics
that support 4 mA ... 20 mA HART
®
protocol, frequency, or fieldbus output.
The density measurement system includes:
• Source holder
• Detector assembly
• Communication device (HART modem with PC and VEGA software or
Emerson Field Communicator 375)