ACTUATORS
Actuators are connected to the device via digital out
puts 1, 2, 3 and 4, which are of the type “Open
colle
ctor”.
Using the “Configurator” program, you can
switch the first digital output to a frequency mode by
checking the corresponding field (see “Settings”
part). The output frequency is set by a command from the
server or through the "Configurator".
Permissible load on each digital output 0.5 A
To increase the load on the outputs of the device, you must use an external relay. The relay
connection diagram is shown below.
INPUTS
Vega MT X CAN monitoring device has three multifunctional inputs that can operate in four modes:
o
Analog;
o
Digital;
o
Frequency;
o
Pulse.
In analog mode, the input voltage is measured. Such an input can be used for sensors whose
readings vary in a certain range.