ISD Component Installation
Vapor Flow Meter Installation - Dispenser
1.
A Transmitter /battery pack pair must be installed with the Veeder-Root Vapor Flow Meter (VFM) in the
dispenser cabinet.
2.
Install the VFM in the dispenser following instructions accompanying the VFM.
3.
Using two taptite screws from the kit, attach the Transmitter housing to the side of the battery support bracket
that has the two circular slots (see Figure 13). Do not tighten screws at this time.
4.
Remove the cover from the transmitter. Attach the non-connector end of the cable from the VFM to the
transmitter as described in the section below entitled “Connecting Sensor Cables To The Transmitter” on
page 24, then attach the transmitter/L bracket assembly to the back mounting surface using two #10 taptite
screws from the kit.
5.
Determine a support location within the dispenser cabinet that will allow you room for the transmitter/battery
support bracket. Clamp the bracket to an available support structure (see Figure 14).
6.
Rotate the Transmitter antenna as close as possible to a horizontal position then tighten two mounting screws
in housing.
7.
Insert the battery pack into its support bracket - do not connect the battery cable to the battery pack at this
time.
Figure 13. Attaching Transmitter to battery support bracket
LEGEND FOR NUMBERED BOXES IN Figure 13
1.
Transmitter
2.
#10 x 1/2” taptite screws (2)
3.
Battery support bracket
964-20.ep
s
3
2
1
19-19