background image

18

3.

Attach Transmitter to support bracket as shown in Figure 15.

Figure 15.   Attach Transmitter to 332295–001 Bracket

LEGEND FOR NUMBERED BOXES IN Figure 15

1. Transmitter
2. #10–32 x 12.7mm (½”) taptite screw – 

2 places

3. Support bracket

3

2

1

Содержание TLS-RF Series

Страница 1: ...TLS RF Series 4 Wireless System Quick Startup Guide Manual No 577014 483 Revision C...

Страница 2: ...l or consequential damages in connection with the furnishing performance or use of this publication The information contained in this publication may be subject to change without notice This publicati...

Страница 3: ...IP Address Username and Password 8 Figure 5 Configure Ethernet IP Settings Windows 10 9 Figure 6 Configure Ethernet IP Settings Windows 11 10 Figure 7 Example Gateway Login Page 11 Figure 8 Gateway Lo...

Страница 4: ...Foreign Language Manual Notice for the web address from where 577014 497 can be downloaded Veeder Root safety and regulatory information relative to this product is available at https www veeder com...

Страница 5: ...k 1 577014 245 ATEX EU Foreign Language Manual Notice 1 330020 528 or 330020 835 Installation Hardware Kit Includes hardware required to install Transmitter and Bat tery Pack 1 only for kits that incl...

Страница 6: ...ure 1 Gateway Panel interface LEGEND FOR NUMBERED BOXES IN Figure 1 1 Gateway reset 2 Gateway DC power connector 3 Gateway Ethernet RJ 45 connector 4 Gateway antenna connector type RP SMA female 5 Gat...

Страница 7: ...ls PWR and GND Observe polarity 7 Power input terminals PWR and GND 8 Cable from Battery Pack observe polarity 9 Cable from surge protector 10 Cord grip bushing 11 Orient tapered bushing as shown when...

Страница 8: ...ctors 9 Power up the Gateway 10 Verify that the Gateway setup screen status is Registration Successful 11 Record the following Transmitter identification information location e g tank number and produ...

Страница 9: ...and will not interfere with employee traffic The Gateway antenna should be at least 25 4mm 1 clear from any objects and be kept as far away as possible from electrically conductive in particular metal...

Страница 10: ...y password to enhance the security of the TLS RF Series 4 Wireless System Perform the following steps to change the Gateway password 1 Read the Gateway default IP address username and password from th...

Страница 11: ...device s Ethernet IP settings according to the IP address read from the Gateway label For example if the IP address is 192 168 4 15 then set the device s Ethernet IP settings to the following Disable...

Страница 12: ...and Figure 6 Windows 11 for example Ethernet IP setting configuration steps Figure 5 Configure Ethernet IP Settings Windows 10 1 Right click and select Properties 2 Select Internet Protocol Version 4...

Страница 13: ...igure Ethernet IP Settings Windows 11 1 Select Network Internet 2 Within the Ethernet IP assignment section select Edit 3 Configure Ethernet IP settings as shown Preferred DNS can be changed as desire...

Страница 14: ...gin page is loaded as shown in Figure 7 Figure 7 Example Gateway Login Page 4 Enter the username e g admin and password e g Admin12345678 read from the Gateway label into the corresponding login page...

Страница 15: ...ount Page 6 Within the Change My Password window enter the password read from the Gateway label into the Old Password field and enter the desired new password which must follow the guidelines listed i...

Страница 16: ...down toward the floor 3 Screw the Gateway antenna onto the antenna connector on the bottom of the unit 4 If the mounting wall is metal rotate the Gateway antenna up 45 degrees from vertical otherwise...

Страница 17: ...can be returned to its factory default state by holding the Gateway s reset button for between 5 and 30 seconds and then releasing Note that holding the Gateway s reset button for less than 5 seconds...

Страница 18: ...ateway through an Uninterruptible Power Supply UPS to retain its date time through power outages Enable SNTP Administration User Accounts Change the password Access Configuration Includes the followin...

Страница 19: ...s properly seated within the cover Screws are tightened to between 14 and 18 inch pounds 1 Attach the two 12 7 mm 1 2 conduit clamps to the two riser hangers from the installation hardware kit 330020...

Страница 20: ...14 Attaching 12 7mm Conduit to 12 7mm Clamps on Riser LEGEND FOR NUMBERED BOXES IN Figure 14 1 Probe Riser 2 Customer supplied 12 7mm 1 2 con duit For a sump installation the conduit should be of an a...

Страница 21: ...smitter to support bracket as shown in Figure 15 Figure 15 Attach Transmitter to 332295 001 Bracket LEGEND FOR NUMBERED BOXES IN Figure 15 1 Transmitter 2 10 32 x 12 7mm taptite screw 2 places 3 Suppo...

Страница 22: ...port bracket as shown in Figure 16 Figure 16 Attach Conduit Clamps to Support Bracket LEGEND FOR NUMBERED BOXES IN Figure 16 1 10 32 x 12 7mm taptite screw 2 places 2 12 7mm 1 2 plastic clamp 2 places...

Страница 23: ...ghten the two conduit clamps see Figure 17 Insert the Battery Pack into its support bracket cradle as shown Figure 17 Installing Support Bracket at Recommended Transmitter Antenna Position 6 Get the s...

Страница 24: ...Positioned so antenna tip is within 25 4mm 1 of sump cover 3 Battery Pack 4 Tie wrap Surge Protector to riser 5 Single channel surge protector from instal lation hardware kit Install within 1m 3 feet...

Страница 25: ......

Страница 26: ...MultiTech P N 82131160L...

Отзывы: