RS-232 Commands
Function Code: 624
45
Function Code: 624
Function Type:
Set Tank High Water Level Limit
Version 1
Command Format:
Set:
Inquire:
Display:
<SOH>S624TTHH.H
Display:
<SOH>I624TT
Computer:
<SOH>s624TTFFFFFFFF
Computer:
<SOH>i624TT
Notes:
1.
TT -
Tank Number (Decimal, 00 = all)
2.
HH.H -
High Water Level Limit, (Decimal)
3.
FFFFFFFF -
High Water Level Limit, (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I624TT
TT HH.H
<ETX>
Typical Response Message, Computer Format:
<SOH>i624TT0000000000TTFFFFFFFF...
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. 0000000000 -
Not Used.
2.
TT -
Tank Number (Decimal, 00 = all)
3.
FFFFFFFF -
High Water Level Limit, (ASCII Hex IEEE float)
4.
&& -
Data Termination Flag
5.
CCCC - Message
Checksum