RS-232 Commands
Function Code: 605
38
Function Code: 605
Function Type:
Set Tank 4-Point (Full, 3/4, 1/2, & 1/4 Height) Volumes Version 1
Command Format:
Set:
Inquire:
Display:
<SOH>S605TTGGGGGGggggggGGGGGGgggggg
Display:
<SOH>I605TT
or:
<SOH>S605TTGGGG,gggg,GGGG,ggg
Computer:
<SOH>s605TTFFFFFFFFffffffffFFFFFFFFffffffff
Computer:
<SOH>i605TT
Notes:
1.
TT -
Tank Number (Decimal, 00 = all)
2.
GGGGGG -
Full Height Volume, Gallons (Decimal)
3.
gggggg -
3/4 Height Volume, Gallons (Decimal)
4.
GGGGGG -
1/2 Height Volume, Gallons (Decimal)
5.
gggggg -
1/4 Height Volume, Gallons (Decimal)
6.
FFFFFFFF -
Full Height Volume, Gallons (ASCII Hex IEEE float)
7.
ffffffff -
3/4 Height Volume, Gallons (ASCII Hex IEEE float)
8.
FFFFFFFF -
1/2 Height Volume, Gallons (ASCII Hex IEEE float)
9.
ffffffff -
1/4 Height Volume, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I605TT
1 9728 7296 4864 2432
<ETX>
Typical Response Message, Computer Format:
<SOH>i605TT0000000000TTFFFFFFFFffffffffFFFFFFFFffffffff...
TTFFFFFFFFffffffff&&CCCC<ETX>
Notes:
1.
0000000000 -
Not Used.
2.
TT -
Tank Number (Decimal, 00 = all)
3.
FFFFFFFF -
Full Height Volume, Gallons (ASCII Hex IEEE float)
4.
ffffffff -
3/4 Height Volume, Gallons (ASCII Hex IEEE float)
5.
FFFFFFFF -
1/2 Height Volume, Gallons (ASCII Hex IEEE float)
6.
ffffffff -
1/4 Height Volume, Gallons (ASCII Hex IEEE float)
7.
&& -
Data Termination Flag
8.
CCCC -
Message Checksum
Содержание TLS-50 Series
Страница 1: ...Manual No 577013 608 Revision N Site Prep Manual TLS 50...
Страница 75: ......
Страница 76: ...For technical support sales or other assistance please visit www veeder com...