RS-232 Commands
Function Code: 607
40
Function Code: 607
Function Type:
Set Tank Diameter
Version 1
Command Format:
Set:
Inquire:
Display:
<SOH>S607TTHHH.HH
Display:
<SOH>I607TT
Computer:
<SOH>s607TTFFFFFFFF
Computer:
<SOH>i607TT
Notes:
1.
TT -
Tank Number (Decimal, 00 = all)
2.
HHH.HH -
Tank Diameter (Decimal)
3.
FFFFFFFF - Tank Diameter (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I607TT
TT HHH.HH
<ETX>
Typical Response Message, Computer Format:
<SOH>i607TT0000000000TTFFFFFFFF...
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. 0000000000 -
Not Used.
2.
TT -
Tank Number (Decimal, 00 = all)
3.
FFFFFFFF -
Tank Diameter, (ASCII Hex IEEE float)
4.
&& -
Data Termination Flag
5.
CCCC -
Message Checksum