31
Crown moulding strip, side
Light bar, side
Crown moulding strip
Light bar, front edge under door
Light bar
3.6 CROWN MOULDING STRIPS AND LIGHT BARS
Crown moulding strips B and straight are fitted with angle braces and
screws (TKX Ø4x15). The positioning of the crown moulding strip on the
front of wall cabinets/tall cabinets is a matter of taste, but the images
provided are recommendations. In type B, the strip sits with half its width
outside the frame. In type D, the bevel sits on the bottom part of the strip,
level with the front of the frame. A straight combination strip is placed so
that the radius is outside the door. In the case of a rustic combination strip,
this can also be installed with some type of strip instead of an angle brace
(not included in the delivery from Vedum).
Installing crown moulding strips on the side of a wall cabinet/tall
cabinet. The positioning constitutes alternative recommendations.
In type B, the back of the strip sits in the middle of the cabinet side.
In type D, it sits with the screw in the centre of the cabinet side (NB:
always drill pilot holes). In combination strips, they sit so that the
radius is outside the side.
The light bar is fitted with an angle brace and screws (TKX Ø4x15).
Positioning of the light bar on the front of a wall cabinet is a matter of
taste, but the images provided are recommendations. In types A and B, the
strip sits with half its width outside the frame. Combination strip, straight is
fitted so that the radius is level with the door.
Fitting the light bar on the side of a wall cabinet is a matter of taste, but
the images provided above are recommendations. In type B, the strip is
positioned such that the round portion sits outside the side. In combination
strip, straight, the strip is positioned such that the radius is outside the side.
In combination strip, straight, painted version, the joint for the covering
should be turned towards the cabinet. In the case of a fan, you should mitre
in the light bar strips and install the light bar strip against the wall.
3. Installing wall cabinets
Combi-
nation
strip B
3852
Crown
moulding
strip D
3854
Combina-
tion strip,
straight
3857
Combination
strip, straight
3856,
3858,
3885
Crown moulding strip, front edge over door
Ceiling connector and crown moulding
strip in combination, side.
Ceiling connector and crown moulding
strip in combination, front edge over door.
Dimensions from the wall to the mounting
block: for wall cabinet 302 mm, for tall
cabinet 580 mm.
A
3851
Combination
strip B
3852
Combination
strip
straight
3857
A
3851
Combina-
tion strip B
3852
Combina-
tion strip
straight
3857
Combi-
nation
strip,
rustic
3859
Combi-
nation
strip B
3852
Crown
moulding
strip D
3854
Combi-
nation
strip,
straight
3857
Combina-
tion strip,
straight
3856,
3858,
3885
Combi-
nation
strip,
rustic
3859
Combina-
tion strip,
rustic
3859
Combina-
tion strip,
rustic
3859
Combina-
tion strip,
straight
3856,
3858,
3885
Combi-
nation
strip,
straight
3856,
3858,
3885
In the case of smaller distances
between cabinet and ceiling, an
articulated screwdriver may be
required.