Controls and Indicators

FUNCTION BUTTONS:

Battery Type

(Step 1) allows the user to select Wet, Gel or AGM type of battery

for an efficient and safe charge. Most automotive batteries are Wet batteries. Refer
to the battery manufacturer’s specifications for battery type.

4/15/30/50 AMP (Charge Rate Selector)

(Step 2) allows the user to select the

charge rate based on battery size. This selection and the actual battery charge rate
are monitored by the microprocessor. The charger will stop charging if the rate is too
fast or too slow for the battery size or condition.

150 AMP (Engine Start)

places the charger in an engine start sequence. This

button will not be activated unless the charger is in the 50 amp charge mode; set the
4/15/30/50 AMP button to 50 amps first to activate this button.

Battery Recond.

is an automatic mode that, once started, continues for 24 hours

and then stops. A series of electrical pulses breaks the crystalline form of lead sulfate
to turn these chemicals into useful battery electrolytes. More than 24 hours may be
needed to restore. Periodic reconditioning is recommended to maintain a battery's
optimum performance. However, if 5 cycles does not improve battery performance,
discontinue and recycle the battery. 

Alternator Check

is a quick check that measures the battery voltage. This check is

repeated at various electrical load levels and the tests allow the user to determine if
the alternator can keep up with the loads. It can indicate whether alternator service
may be required.

INDICATOR:

Large (.375”) 3-Character Digital Display

in the upper left of the control panel

indicates the various conditions and/or status codes:
Status Codes are described in the following chart and on the back of charger.

CONTROL PANEL

DIGITAL READOUT

CIRCULATING PATTERN

2

Stage Two —

Absorption Charge maintains the maximum possible charge at a

constant, safe, predetermined voltage. During this phase, the charging voltage remains
constant, while the actual charging current is reduced to allow for the maximum proper
internal chemical energy transfer. At the end of Stage 2, the charger will automatically
move into Stage 3 charge mode.

Stage Three —

Top-Off Charge — voltage is automatically maintained and

reduced to a predetermined level while current is adjusted for a safe, effective battery
charge. At the conclusion of Stage 3, the unit will BEEP signaling the completion of
the charging cycle.
The Automatic Float Charge feature is ideal for maintaining a battery. It automatically
tops off battery as needed to keep battery fully charged all the time.

FEATURES

• This unit has four charge rate settings, accessed by the 4/15/30/50 AMP button:

a) 4 amps: smaller batteries, such as in lawn mowers, snowmobiles, 

motorcycles, etc.

b) 15 amps: mid-sized batteries, such as in small cars
c) 30 amps: automobiles and light trucks
d) 50 amps: large truck batteries, banks of RV batteries

• 150 amp engine start
• Automatic Temperature Compensation
• Battery type selection
• Digital diagnostics
• Alternator voltage and battery voltage check
• Digital display shows charge rate, operating mode, fault codes and FUL 

when charged

• 1 minute engine start
• 3 stage high-frequency switch mode automatic rapid charging
• Spark resistant reverse polarity and short circuit protection for user
• Built-in battery reconditioning (desulfate)
• Equalization function
• Lightweight, high-efficiency design
• Cables and clamps self-stored
• Microprocessor control (Digital Smart Control)/High frequency power
• Compensates for low AC from extension cord use

VEC1098A_Manual_082606  8/26/06  12:56 PM  Page 2

Содержание VEC1098A

Страница 1: ...arable design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for the shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does not cover accessories such as charging ada...

Страница 2: ...AD THIS MANUAL EACH TIME BEFORE USING YOUR CHARGER AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products and on engine 3 This equipment employs parts switches relays etc that produce arc...

Страница 3: ...oubleshooting 10 INTRODUCTION Thank you for selecting the VEC1098A 50 30 15 4 Amp Smart Battery Charger With proper care and use it will give you years of dependable service This battery charger has a high charge rate of up to 50 amps a low charge rate of 4 amps and 150 amps of engine starting power It is designed for charging only 12 volt lead acid batteries conventional automotive maintenance fr...

Страница 4: ...ribed in the following chart and on the back of charger CONTROL PANEL DIGITAL READOUT CIRCULATING PATTERN 2 Stage Two Absorption Charge maintains the maximum possible charge at a constant safe predetermined voltage During this phase the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer At the end of Stag...

Страница 5: ...o give it some charge If after approximately 2 hours the display just shows F03 then the battery will not charge Charger occasionally sounds a beep and displays 0 0 during self test or charging stage changes 3 Pressing the 4 15 30 50 AMP button again advances charging rate to 15 amps pressing once more advances charging rate to 30 amps and again to 50 amps Pressing the button again will turn OFF t...

Страница 6: ...ge most of the lead sulfate is dissolved and the plates are free of this insulation If a battery remains in a discharged condition over a longer period of time the lead sulfate changes to a hard crystalline form making a full charge difficult to achieve Reconditioning may save a sulfated battery BATTERY RECONDITION MODE should only be used with 10 amp hour Ah or larger capacity lead acid batteries...

Страница 7: ...any codes This initial charge will check the battery for shorted cells F01 open cells F03 or battery too low to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Remove or disconnect the vehicle s battery when reconditioning 1 Make sure the charger is in initiation state with a circulating pattern on the display or in ch...

Страница 8: ...ing and equalizing we recommend taking your battery to a certified automotive service center for evaluation F04 Overtime Condition F04 appears when charging time exceeds 18 hours You may be using a charge current rate too low for a large battery Select higher charge rate to charge the battery F05 Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charge...

Отзывы: