TROUBLESHOOTING

Display Indications/Common Problems/Possible Solutions 

No Functions

• Check and make sure the charger is plugged into a live 110/120 volt AC outlet.
• Follow the steps outlined in the Operating Instructions section.

F01 — Internal Shorted Cell Battery

If the battery being charged has an internal shorted cell, the F01 will show. We
recommend taking your battery to a certified automotive service center for evaluation.

F02 — Bad Battery Connection or Battery Voltage Too Low to Accept
Charge

When F02 appears, the most common cause is poor connection to battery.
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual

to disconnect AC cord and clamps, clean battery terminal and reconnect.

• If the situation persists, we recommend taking your battery to a certified automotive

service center for evaluation.

F03 — Sulfate or Unchargeable Battery

F03 appears when the battery is highly sulfated and cannot accept normal charge
current.
• Follow the steps in “Recondition Mode” to recondition the battery.
• Follow the steps in “Equalizing” to equalize the battery.
• If the situation persists after reconditioning and equalizing, we recommend taking

your battery to a certified automotive service center for evaluation.

F04 — Overtime Condition

F04 appears when charging time exceeds 18 hours.
You may be using a charge current rate too low for a large battery. Select higher
charge rate to charge the battery.

F05 — Overheated Condition

The ventilation grill that prevents the air from flowing in and out of the charger may
be blocked.
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual

to disconnect AC cord and clamps, allow the unit to cool for 30 minutes and 
reconnect.

• Make sure there is ample ventilation before resuming operation.

F06 — Reverse Polarity

The connections to the battery’s POSITIVE and NEGATIVE terminals are incorrect.
Follow the steps outlined in “Important Safety Instructions” at the front of this manual
to disconnect AC cord and clamps and reconnect to battery with correct polarity.

F07 — Alternator Voltage

Alternator output voltage is out of typical operation range.

Charging a Very Cold Battery

If the battery to be charged is very cold (in temperatures below freezing — 0°C/
32°F), it cannot accept a high rate of charge. The initial charge rate will be low. The
charge rate will increase as the battery warms. Never attempt to charge a frozen
battery. 

VEC1098A_Manual_082606  8/26/06  12:56 PM  Page 10

Содержание VEC1098A

Страница 1: ...arable design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for the shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does not cover accessories such as charging ada...

Страница 2: ...AD THIS MANUAL EACH TIME BEFORE USING YOUR CHARGER AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products and on engine 3 This equipment employs parts switches relays etc that produce arc...

Страница 3: ...oubleshooting 10 INTRODUCTION Thank you for selecting the VEC1098A 50 30 15 4 Amp Smart Battery Charger With proper care and use it will give you years of dependable service This battery charger has a high charge rate of up to 50 amps a low charge rate of 4 amps and 150 amps of engine starting power It is designed for charging only 12 volt lead acid batteries conventional automotive maintenance fr...

Страница 4: ...ribed in the following chart and on the back of charger CONTROL PANEL DIGITAL READOUT CIRCULATING PATTERN 2 Stage Two Absorption Charge maintains the maximum possible charge at a constant safe predetermined voltage During this phase the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer At the end of Stag...

Страница 5: ...o give it some charge If after approximately 2 hours the display just shows F03 then the battery will not charge Charger occasionally sounds a beep and displays 0 0 during self test or charging stage changes 3 Pressing the 4 15 30 50 AMP button again advances charging rate to 15 amps pressing once more advances charging rate to 30 amps and again to 50 amps Pressing the button again will turn OFF t...

Страница 6: ...ge most of the lead sulfate is dissolved and the plates are free of this insulation If a battery remains in a discharged condition over a longer period of time the lead sulfate changes to a hard crystalline form making a full charge difficult to achieve Reconditioning may save a sulfated battery BATTERY RECONDITION MODE should only be used with 10 amp hour Ah or larger capacity lead acid batteries...

Страница 7: ...any codes This initial charge will check the battery for shorted cells F01 open cells F03 or battery too low to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Remove or disconnect the vehicle s battery when reconditioning 1 Make sure the charger is in initiation state with a circulating pattern on the display or in ch...

Страница 8: ...ing and equalizing we recommend taking your battery to a certified automotive service center for evaluation F04 Overtime Condition F04 appears when charging time exceeds 18 hours You may be using a charge current rate too low for a large battery Select higher charge rate to charge the battery F05 Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charge...

Отзывы: