CHARGING IF BATTERY IS OUTSIDE OF VEHICLE

a) Check polarity of battery posts- For top-mounted battery posts, the positive post (marked POS, P, +) usually has a larger  

diameter than the Negative battery post (marked NEG, N, –). For side-mounted battery terminal connections the
Positive terminal is red, the Negative terminal is black.

b) Attach a 24-inch (minimum length) 6 AWG insulated battery cable to the Negative battery post (marked NEG, N, -).
c) Connect the Positive (RED) battery clamp to the Positive battery terminal (marked POS, P, + or red).
d) Stand as far back from battery as possible, and do not face battery when making final connection.
e) Carefully connect Negative (BLACK) charger clamp to the free end of the battery cable connected to the negative 

terminal. Connect the charger's power cord to a grounded 110/120VAC power outlet (refer to Appendix A for
approx. charge times).

f) Set charger's charge rate to appropriate setting according to battery size.
g) When charging is complete, disconnect cables and clamps in reverse order from which they were connected.

CHARGING TIMES

The VEC1087 A, fully automatic battery charger will automatically adjust the charge rate as the battery charges and stops
charging when the battery is fully charged. If you require some estimate of the time it takes to charge a battery refer to
Appendix A (page 9) for these details.

CARE AND MAINTENANCE

With minimal maintenance, the Vector VEC1087 A 2/6/10A Smart Battery Charger will provide years of dependable
service.

• After each use, clean the battery charger clamps - be sure to remove any battery fluid that will cause corrosion

of the copper clamps.

• Clean the outside case of the charger with a soft cloth and, if necessary, mild soap solution.
• Keep the charger cords loosely coiled during storage to prevent damage to the cords. Do not use charger if cords or

clamps have been damaged in any way - call Vector Technical Support Department toll-free: (866) 584-5504 for
replacement cords/clamps.

Deep cycle batteries may need longer charging time. It is recommended to repeat the charging cycle 
a second time beginning with the 2A rate. 

Содержание VEC1087 A

Страница 1: ...rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b That extension cord is properly wired and in good electrical ...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ...let 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position AC and DC cords to reduce risk of damage by hood door ...

Страница 4: ...ion regulation charge the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode This is ideal for topping off batte...

Страница 5: ... a second time will advance the charge rate to 6A then 10A Pressing the button switch again will turn OFF the charger output and all LED bars will be unlit To return to 2A press the Charge Rate button switch This charger has three user selected charge rates 2 6 and 10 amps Pressing the 2 6 10A switch button selects the desired charge rate The selected Charge Rate is indicated by a lit vertical LED...

Страница 6: ...n charging is completed disconnect cables and clamps in reverse order from which they were connected NOTE Use of Extension Cords When using an extension cord observe the following important safety information Before using any extension cord ensure that the wire size is at least 14 AWG for up to 100 feet and 12 AWG for longer than 100 feet Use only a good quality good condition UL approved extensio...

Страница 7: ...size g When charging is complete disconnect cables and clamps in reverse order from which they were connected CHARGING TIMES The VEC1087 A fully automatic battery charger will automatically adjust the charge rate as the battery charges and stops charging when the battery is fully charged If you require some estimate of the time it takes to charge a battery refer to Appendix A page 9 for these deta...

Страница 8: ...sulfated Sulfated batteries cannot accept a high rate of charge since the internal plates are coated with lead sulfate To see if a battery in this condition can be saved take it to a service station or battery distributor for professional evaluation and service INTERNAL SHORT CELL BATTERY If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on...

Страница 9: ...F CHARGE 75 50 25 0 2 AMPS 7 HRS 13 HRS NR NR 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS 10 AMPS 1 5 HRS 3 HRS 4 HRS 5 HRS Not recommended The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged batter...

Отзывы: