background image

VEC1087 A

REV101103

2

PERSONAL PRECAUTIONS AND SAFETY

1. Another person should be close enough to come to your aid when you work near a lead-acid battery.
2. Fresh water and soap should be nearby in case battery acid contacts skin, clothing, or eyes.
3. Wear eye protection and protective clothing. Avoid touching eyes or skin while working with a battery. If acid particles

or corrosion gets into eyes immediately flood eye with cold water (Eye Wash Station) for at least 10 minutes and get
medical attention immediately.

4. If battery acid contacts skin or clothing, wash immediately with soap and water.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. CAUTION: Dropping metal tool or other object onto battery may cause spark, short-circuit battery or other electrical

components and may cause explosion.

7. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery.

Lead-acid batteries can produce a short-circuit current high enough to cause a severe burn.

GROUND AND AC POWER CORD CONNECTION

Charger should be grounded to reduce risk of electric shock. Charger is equipped with an AC cord having grounding
conductor and a grounding plug. The plug must be plugged into a properly installed and grounded 110/120VAC outlet
in accordance with all local codes and ordinances. (See Figure 1.)

This battery charger is for use on a 110/120VAC circuit, and has a grounding plug that looks like the plug shown in
FIGURE 1A. If a properly grounded outlet is not available, a temporary adapter (like the adapter shown in FIGURE 1B),
may be used to connect this plug to a two-pole receptacle as shown in FIGURE 1B. The temporary adapter should be
used ONLY until a properly grounded outlet can be installed by a qualified electrician.

The green-colored rigid ear or tab extending from adapter must be connected to a properly grounded outlet.  Make
certain it is grounded. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter
ground tab to outlet cover plate and connect to grounded outlet.

GROUNDING PIN (A)

ADAPTER (B)

GROUNDING
MEANS

METAL SCREW

USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS 
NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A 
QUALIFIED ELECTRICIAN.

DANGER! 

NEVER

alter AC cord or plug – if it will not fit outlet, have proper outlet installed by a qualified

electrician. Improper connection may result in an electric shock.

DANGER! 

Before using adapter as shown (FIGURE 1B), be sure the center screw of outlet plate is grounded.

FIGURE 1A

FIGURE 1B

Содержание VEC1087 A

Страница 1: ...rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b That extension cord is properly wired and in good electrical ...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ...let 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position AC and DC cords to reduce risk of damage by hood door ...

Страница 4: ...ion regulation charge the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode This is ideal for topping off batte...

Страница 5: ... a second time will advance the charge rate to 6A then 10A Pressing the button switch again will turn OFF the charger output and all LED bars will be unlit To return to 2A press the Charge Rate button switch This charger has three user selected charge rates 2 6 and 10 amps Pressing the 2 6 10A switch button selects the desired charge rate The selected Charge Rate is indicated by a lit vertical LED...

Страница 6: ...n charging is completed disconnect cables and clamps in reverse order from which they were connected NOTE Use of Extension Cords When using an extension cord observe the following important safety information Before using any extension cord ensure that the wire size is at least 14 AWG for up to 100 feet and 12 AWG for longer than 100 feet Use only a good quality good condition UL approved extensio...

Страница 7: ...size g When charging is complete disconnect cables and clamps in reverse order from which they were connected CHARGING TIMES The VEC1087 A fully automatic battery charger will automatically adjust the charge rate as the battery charges and stops charging when the battery is fully charged If you require some estimate of the time it takes to charge a battery refer to Appendix A page 9 for these deta...

Страница 8: ...sulfated Sulfated batteries cannot accept a high rate of charge since the internal plates are coated with lead sulfate To see if a battery in this condition can be saved take it to a service station or battery distributor for professional evaluation and service INTERNAL SHORT CELL BATTERY If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on...

Страница 9: ...F CHARGE 75 50 25 0 2 AMPS 7 HRS 13 HRS NR NR 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS 10 AMPS 1 5 HRS 3 HRS 4 HRS 5 HRS Not recommended The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged batter...

Отзывы: