Limited Warranty Policy 

 

Veco NA, LLC (Company) warrants that if any part of a new system that includes the accompanying 
product proves to be defective to the original user in material or workmanship within the limits of the 
schedule below, the company will, at the company's option, either replace or repair that part without 
charge. 

 

Compressor (excluding Controller): ….. 5 years from date of purchase or purchase of a new vessel 
Electronic components:  ………………. 2 years from date of purchase or purchase of a new vessel   
Mechanical components: ……………… 1 year from date of purchase or purchase of a new vessel 

 

Note 

-

 

Items sold individually, i.e. not as part of a complete system, carry a one year warranty only. 

 

-  Items replaced or repaired under warranty are covered only for the remainder of the term of 

the original warranty. 

 

This warranty does not cover: 

 

 

Any field labor or other costs for inspection, testing, removal, transportation, or installation of any 
component unless pre-authorized by the Company and issuance of an RMA number.  

 

 

Damage,  failure,  or  malfunction  due  to,  or  arising  from,  improper,  faulty,  or  unapproved 
installation,  servicing,  and/or  application,  and  from  failing  to  strictly  follow  the  guidelines 
included with the equipment and in the Installation & Instruction Manual.  

 

 

Any component of a system that is not comprised solely of Frigoboat supplied refrigeration parts, 
or parts supplied or expressly approved by Coastal Climate Control, Inc. 

 

 

Damage, failure, or malfunction resulting from accident, misuse, abuse, neglect, mishandling, 
alteration, modification, Acts of God, or service by personnel other than those pre-authorized by 
the Company.   

 

 

Damage, failure, or malfunction resulting from inadequate or faulty power supply to the system, or 
improper, faulty, or unsafe vessel wiring. 

 

 

Damage,  failure,  or  malfunction  due  to  foreign  substances  being  injected  into  the  system, 
including, but not limited to; additional refrigerant oil, “conditioner”, flushing fluid, Thawzone, 
leak stopper and/or leak detecting liquid, etc. 

 

No responsibility is assumed for injury, illness or death due to medical supplies and/or drugs being 
subjected to incorrect temperatures while stored in an application cooled by a Frigoboat refrigeration 
system. 
No responsibility is assumed for any special, incidental, or consequential damages. 

Note

  Some states do not allow the exclusion or limitation of incidental or consequential damages so 

the above exclusion or limitation may not apply.  

 

 

In the event of a component or system failure or malfunction, please contact the dealer you purchased 

the system from. If further help is required, please call Veco NA, LLC at 301 352 6962. If requested, return 
faulty  part,  freight  pre-paid,  together  with  proof  of  purchase.  No  returns  will  be  accepted  without  prior 
authorization and the issuance of an RMA number by Veco NA. Damage due to shipping is not covered in this 
warranty and so it is suggested that the shipment be insured by the sender. If the part(s) is found to be defective 
due to faulty materials or workmanship, it will be repaired or replaced free of charge and shipped freight pre-
paid to an address within the contiguous USA. 

If warranty service is required in areas other than North America and the Caribbean, please visit the 

manufacturer’s web site at www.veco.net. 

Содержание Frigoboat Capri 35F

Страница 1: ...s Air Cooled Pumped Water Cooled Keel Cooled and Keel plus Air Cooled Systems using Secop formally Danfoss BD 35 or BD 50 compressors It is important to read this manual thoroughly before installing a...

Страница 2: ...it or an Air Add On air cooled condenser is installed together with a Keel Cooler ensure that the fan is operated only when the boat is out of the water and then switched off when the boat is launched...

Страница 3: ...Capri 35F Capri 50F Air cooled These units are designed to be mounted with compressor right way up on a horizontal surface in areas where they will not be susceptible to physical or water damage but...

Страница 4: ...ll deliver 12v even if the system is connected to a 24v supply Full wiring instructions are included with the compressor If more than one W35 or W50 is sharing a single water pump they must be plumbed...

Страница 5: ...ion of the transom that is below the waterline when at rest Keep the two tubes from the Keel Cooler separate from each other and do not insulate them It is extremely important to orientate the cylindr...

Страница 6: ...control running at 2000 RPM All others must have either a manually adjustable compressor speed controller like a Speed Board or alternatively an automatic smart speed control such as the Merlin II Sma...

Страница 7: ...to the controller there may be a delay of up to 30 seconds before the compressor starts Note 2 If initial power is applied that is above the low voltage threshold but below the cut in voltage value se...

Страница 8: ...els in the evaporator Never attempt to bend a plate downwards over a pipe as damage may result The area to be bent should be warmed with a hair dryer or heat gun to approximately 200 F before bending...

Страница 9: ...lastic plate on the evaporator so that it lays in the special grooves of the plastic plate Finish by tightening the clamping screw If using the Coastal MK3 digital thermostat the sensor mounts on the...

Страница 10: ...refully coiled up and secured out of the way to avoid damage When securing the sensing tube make sure contact is made only with the evaporator at the point where it is attached under the plastic mount...

Страница 11: ...top of the barrier 1 should be sufficient or 3 or more holes of the same size as the one behind the spillover fan All other holes gaps etc in the barrier must be completely sealed including drains 8...

Страница 12: ...talled until the very last moment when you are ready to connect the system together Once the dust caps have been removed it is imperative that the exposed components and surfaces be kept free of dust...

Страница 13: ...tion Use either a breaker or fast blow fuse with 15 amp rating for a 12v supply or 7 5 amp for 24v 10 4 Connections Power Connect the power supply to the controller on the top two terminals using slip...

Страница 14: ...factory installed on the terminals marked F Black or Blue and Red If the wires are reversed the fan will not run The K50F and W50F models have a small oil cooler fan installed Full instructions are i...

Страница 15: ...oller or compressor to be faulty Controller can be removed by unscrewing the retaining screw or by levering the plastic case over the screw head 11 1 Compressor not running no start attempt Probable c...

Страница 16: ...ty or inadequate power supply Most likely Monitor the supply voltage at the power terminals on the controller before during and after start attempts to ensure that it does not fall below threshold lev...

Страница 17: ...ng in others the system may be low on refrigerant or overcharged Call Veco NA for advice or go to www veco na com Technical Information 7 Drain left unplugged If your icebox is equipped with a drain i...

Страница 18: ...lation 11 5 Excessive frost build up Note This is the result of moist air being allowed to enter the box Problems are compounded when cold dense air leaks from the lower area of the box through an ope...

Страница 19: ...cation Acts of God or service by personnel other than those pre authorized by the Company Damage failure or malfunction resulting from inadequate or faulty power supply to the system or improper fault...